・  Inspection and adjustment by disassembly and cleaning (overhaul) of this 

watch will be performed by SEIKO. When you take the watch to the re-

tailer from whom it was purchased, request that the watch be inspected 

and overhauled by SEIKO.

・  We recommend that you have your watch checked by SEIKO every 3 to 4 

years for long-time use of your watch.

・  The movement of this watch has a structure that consistent pressure is 

applied  on  its  power-transmitting  wheels.  To  ensure  these  parts  work 

together  properly,  periodic  inspection  including  cleaning  of  parts  and 

movement, oiling, adjustment of accuracy, functional check and replacement 

of worn parts is needed.

    Inspection and adjustment by disassembly and cleaning (overhaul) within 3 

to 4 years from the date of purchase is highly recommended for long-time 

use of your watch.

    Contact the retailer from whom the watch was purchased for inspection 

and adjustment by disassembly and cleaning (overhaul) of your watch.

    Make sure that the gasket and push pin will be also replaced with new ones.

● Inspection and adjustment by disassembly and cleaning (overhaul)

CAUTION

Depending on the environment where a diver’s watch is used, its inner parts or movement as 
well as its case or band may be affected. We recommend that you have your watch inspected 
and adjusted by disassembly and cleaning (overhaul) regularly once every 3 to 4 years.

・ For any questions or concerns, contact SEIKO CUSTOMER SERVICE 

CENTER.

88

89

Solutions

Reference pages

Turn  the  crown  to  wind  the  mainspring  and  reset  the  time.  While  you  are 
wearing the watch or when you take it off, check the remaining power shown by 
the power reserve indicator and wind the mainspring if necessary.

Page 67
Page 70

Turn the crown to wind the mainspring and reset the time. If the watch is left at a temperature below 
0 ºC, it may stop if the power reserve indicator is showing less than one-sixth of the power reserve.

Page 67

Return the watch to a normal temperature so that it works accurately as usual, and then reset the time. The watch has been 
adjusted so that it works accurately when it is worn on your wrist under a normal temperature range between 5 ºC and 35 ºC.

Page 70

Correct this condition by moving and keeping the watch away from the magnetic source. If this 
action does not correct the condition, contact the retailer from whom the watch was purchased.

Page 70
Page 80

Reset  the  time.  If  the  watch  does  not  return  to  its  normal  accuracy  after 
resetting the time, contact the retailer from whom the watch was purchased.

Page 70

While  turning  the  crown  to  set  the  time,  the  moment  the  date  changes  is 
midnight. Reset the time making sure that AM/PM is set correctly.

Page 70

■ TROUBLESHOOTING

Troubles

Possible causes

Stoppage 

of the 

watch

The watch stops operating.

The mainspring has not been wound.

The watch stops even though the power 

reserve indicator is not showing  “0.”

The watch has been left at a low temperature 

(below 0ºC).

Wrong 

display of 

the time 

and/or 

date

The  watch  temporarily 

gains or loses time.

The watch has been left at an extremely high 

or low temperature.

The  watch  has  been  left  close  to  an  object 

generating a strong magnetic field.
You dropped the watch, hit it against a hard 

surface or wore it while playing active sports. 

The watch was exposed to strong vibrations.

The  date  changes  during 

daytime.

AM/PM is not correctly set.

90

91

Solutions

Reference pages

Wear the watch for an extended period of time. Or turn the crown to wind 
the mainspring.

Page 66

It takes several seconds before the adjustment function starts working. 
Set the time after the second hand moves for approximately 30 seconds to 
set the time correctly.

Page 76

Contact the retailer from whom the watch was purchased.

■ TROUBLESHOOTING

Troubles

Possible causes

Power 

reserve

Even though you wear the 
watch every day,
the power reserve indicator 
does not move up.

The watch is worn on your wrist only for a 
short  period  of  time,  or  the  amount  of  arm 
movement is small.

Others

Right  after  starting  the 
watch,  it  seems  that  the 
second  hand  moves  more 
quickly  than  usual  when 
setting the time.

When starting the watch, it takes a little time 
before the adjustment function starts working. 

(This is not a malfunction.)

Blur  on  the  dial  gla s s 
persists.

Small  amount  of  water  has  got  inside  the 
watch due to deterioration of the gasket, etc.

※  In the event of any other problem, please contact the retailer from whom the watch was purchased 

or SEIKO CUSTOMER SERVICE CENTER.

92

■ SPECIFICATIONS

1. Features:  3 hands (hour, minute and second hands), Date display, Power reserve indicator

2. Frequency of crystal oscillator: 32,768 Hz

3. Loss/gain (monthly average):  ± 15 seconds ( ± 1 second per day) (worn on your wrist at 

normal temperature range between 5 ºC and 35 ºC)

4. Operational temperature range:  between -10 ºC and +60 ºC

Under a low-temperature condition (below 0ºC), always keep 

at least one sixth of the watch power shown by the power 

reserve indicator.

5. Driving System: ・・ Mainspring (Self-winding type with manual winding function)

6. Hand movement: ・・ Glide-motion hands

7. Continuous operable time:  Approx.  72  hours (Approx.  3  days) (If  the  power  reserve 

indicator shows the power supplied by the mainspring is full 

before starting the watch.)

※  Depending on conditions of use, the continuous operable time 

may become shorter than the above.

8. IC (Integrated Circuit):  Oscillator,  frequency  divider,  and  spring  drive  control  circuit 

(C-MOS-IC): 1 piece

9. Number of jewels: 30 jewels

※ The specifications are subject to change without prior notice due to product improvements.

グランドセイコー専用フリーダイヤル

0120-302-617

本 社 〒 105-8467 東京都港区芝浦 1-2-1

http://www.seiko-watch.co.jp/

受付時間:月曜~金曜 

9:30 ~ 21:00

 

土曜・日曜・祝日  9:30 ~ 17:30

お客様相談室
〒 100-0005 東京都千代田区丸の内 3-1-1 国際ビル
〒 550-0013 大阪市西区新町 1-4-24 大阪四ツ橋新町ビルディング

Содержание Grand Seiko SPRING DRIVE DIVERS 9R65

Страница 1: ...付修正について 28 より正確に時刻を合わせるために 30 使用上の注意とお手入れのしかた 31 性能と型式について 32 ルミブライトについて 33 耐磁性能について 磁気の影響 34 時計に影響を及ぼす身のまわりの磁気製品 35 バンドについて 36 アフターサービスについて 38 補修用性能部品について 39 分解掃除による点検調整 オーバーホール について 40 こんなときは 42 目 次 製品の特長 5 製品取扱上のご注意 6 潜水に際しての注意事項 必ずお読みください 10 潜水前 10 潜水中 12 潜水後 13 各部の名称と主なはたらき 14 基本部分について 14 ねじロック式りゅうずについて 15 回転ベゼルについて 16 回転ベゼルの使いかた 17 ダイバーアジャスターの使いかた 18 ぜんまいの巻き上げについて 20 巻き上げのめやす 20 ...

Страница 2: ...and proper and safe use of the Grand Seiko please read the instruction manual carefully before use We thank you in advance for long time regular use of our product Keep this manual handy for easy reference as necessary For the details of the Spring Drive mechanism refer to the separate volume Spring Drive Handbook Spring Drive works by the power provided by the mainspring Remember to check the pow...

Страница 3: ...d is firmly attached to the watch with spring bars clamp or other parts Screw lock type crown page 61 1 2 3 4 5 6 CAUTION If there are any malfunctions contact the retailer from whom the watch was purchased or SEIKO CUSTIMER SERVICE CENTER 58 59 While diving After diving Please observe the following cautions for use Please follow the care instructions below after diving Rinse the watch in fresh wa...

Страница 4: ...g watch equipped with a manual winding mechanism When the watch is worn on the wrist the motion of your arm automatically winds the mainspring of the watch How to manually wind the mainspring by turning the crown In order to set the time and date after winding the mainspring manually do not relock the crown but continue the procedures How to set the date and time page 70 Guide for winding state of...

Страница 5: ...ainspring is sufficiently wound and the watch is working When setting the date and time ensure that the watch is working 4 Pull out the crown to the first click The second hand continues moving Pull out the crown to the first click 2 Unlock the crown Screw lock type crown page 61 3 While the watch hands show any time between 9 00 PM and 1 00 AM pull out the crown to the second click and turn it co...

Страница 6: ... the band itself Adjust the band with a little clearance with your wrist to ensure proper airflow Make a room for one finger around your wrist when you wear the watch Band The band touches the skin directly and becomes dirty with sweat or dust Therefore lack of care may accelerate deterioration of the band or cause skin irritation or stain on the sleeve edge The watch requires a lot of attention f...

Страница 7: ...rating The mainspring has not been wound The watch stops even though the power reserve indicator is not showing 0 The watch has been left at a low temperature below 0ºC Wrong display of the time and or date The watch temporarily gains or loses time The watch has been left at an extremely high or low temperature The watch has been left close to an object generating a strong magnetic field You dropp...

Отзывы: