Seiko 8J55 Скачать руководство пользователя страница 14

24

Caliber 

number

Battery 

(SB-)

Battery life

9F83

AN

Approximately 

3 years

9F82
9F62
9F61
4J52

AG

4J51

AC

8J55

AN

Approximately 

5 years

  The battery life is the estimated life for a 

watch with a new battery installed. The 
battery in your watch at the time of purchase 
was inserted in the watch at the factory for 
performance checks. It may run down earlier 
than the above-specified period.

  When the battery nears its end, the second 

hand moves at two-second intervals 
instead of normal one-second intervals. The 
watch remains accurate while the second 
hand is moving at two-second intervals.

Frequency of 

crystal oscillator

32,768 Hz (Hz = Hertz...Cycles per second)

Loss/gain 

(Annual rate)

±10 seconds when used on the wrist within a normal 

temperature range (between 5 ºC and 35 ºC) for 

approximately 8 hours per day.

 Monthly rate of loss/gain may amount to approximately 

2 seconds depending on the condition of use.

Operational temperature 

range

Between –10 ºC and +60 ºC

Driving system

Step motor

IC (Integrated Circuit)

C-MOS-IC: 1 piece

  The specifications are subject to change without prior notice due to product 

improvement.

SPECIFICATIONS • BATTERY

(MOVEMENT)

INTERCALARY SECOND (LEAP SECOND)

Normally there are 86,400 seconds in a day. Due to a slight change in the 

earth's rotation, an extra second may be added to one day during the year. 

This is called the intercalary second. Every year the decision is made whether 

such an adjustment is needed. When the adjustment takes place, the standard 

time should be corrected by delaying the standard time one second. To keep 

your SEIKO watch accurate with the world standard time, adjust your watch to 

a time signal whenever such adjustment is made. According to the information 

from the observatories all over the world, the standard time is delayed one 

second simultaneously throughout the world by the Greenwich Royal 

Observatory. In the Greenwich Mean Time, an extra second will be added to 

the one minute between 11:59 p.m. and 0:00 a.m. either on December 31st 

or on June 30th. However, the adjustment may not be made in some years. 

Please check by a newspaper, etc. whether such an adjustment will be made 

or not.

Содержание 8J55

Страница 1: ...www grand seiko com 9F 8J 4J JSYGSA01 1303 QUARTZ...

Страница 2: ...the film and may cause rust The battery in your watch at the time of purchase was inserted in the watch at the factory for performance checks Battery replacement is at cost even within the guarantee p...

Страница 3: ...allergist Other cautions Replacement of the metal band requires professional knowledge and skill Please ask the retailer from whom the watch was purchased for replacement of the metal band as there is...

Страница 4: ...z caliber number starts with 8J or 4J How to check the caliber number The four digit model number on the case back is the caliber number Model Number Regular case back 9F83 00A0 9F83 Caliber Number Ex...

Страница 5: ...careful not to screw the crown in by force as it may damage the slots of the crown When locking the crown turn it slowly with care ensuring that the screw is properly engaged Be careful not to push it...

Страница 6: ...al position in accordance with a time signal The watch immediately starts moving CAUTION You may not be able to set the date and or day when the time on your watch is between midnight and 1 00 a m due...

Страница 7: ...ving CAUTION You may not be able to set the date when the time on your watch is between midnight and 1 00 a m due to the mechanism of the watch This is not a malfunction Please refrain from setting th...

Страница 8: ...t the crown to the second click when the second hand is at the 12 o clock position The second hand stops on the spot Turn the crown to advance the hands until the desired date and day appear Turn the...

Страница 9: ...ments How to set the time After adjusting the hour hand position pull out the crown to the second click when the second hand is at the 12 o clock position The second hand stops on the spot Turn the cr...

Страница 10: ...y disassembly and cleaning overhaul make sure that the gasket and push pin are also replaced with new ones When your watch is inspected and adjusted by disassembly and cleaning overhauled the movement...

Страница 11: ...d the watch case may fall off the bracelet or the clasp may not open If a pin is poking out personal injury may result In such a case refrain from using the watch and request repair Leather band A lea...

Страница 12: ...or stop operating Cellular phone speaker Bag with magnet buckle AC adapter AC powered shaver Magnetic cooking device Portable radio speaker Magnetic necklace Magnetic health pillow Indication on the...

Страница 13: ...1 000 lux Lighting apparatus 40 watt daylight fluorescent light Distance to the watch 1 m 1 000 lux Distance to the watch 3 m 500 lux average room luminance Distance to the watch 4 m 250 lux Troubles...

Страница 14: ...m Step motor IC Integrated Circuit C MOS IC 1 piece The specifications are subject to change without prior notice due to product improvement SPECIFICATIONS BATTERY MOVEMENT INTERCALARY SECOND LEAP SEC...