TECHNICAL GUIDE
Cal. 5T82A
26/26
Copyright©2006 by
ALARM/
WORLD TIME
One or more ALARM hands,
WORLD TIME hands or city
hand have stopped moving
or show an abnormal move-
ment.
The relevant coil is broken.
Measure the coil block resist-
ance. Replace the coil with a new
one if necessary.
An excessive load is being ap-
p l i e d t o t h e A L A R M a n d / o r
WORLD TIME wheels due to dust
or foreign particles adhering to
them or oil starvation.
Clean the relevant parts and lu-
bricate with an adequate amount
of oil.
The step motor shows an
abnormal movement.
There is a crack on the circuit
block switch pattern.
Replace the circuit block with a
new one.
The buttons do not oper-
ate normally.
The amount of oil around the but-
tons is insufficient.
Clean the buttons and lubricate
appropriately.
The circuit block pat tern has
been broken or bent.
Adjust the circuit block pattern
or replace the circuit block with a
new one.
T h e A L A R M d o e s n o t
sound.
The piezoelectric element is bro-
ken or out of alignment.
The upconverter coil is broken.
Replace the circuit block with a
new one.
The ALARM sound is too
small.
The crown falls off.
The winding stem is not securely
installed. (The setting lever and
yoke are disengaged.)
Check the main plate, winding
stem, set ting lever and yoke.
Replace the defective parts with
new ones.
The current consumption
exceeds the standard value.
An excessive load is being ap-
plied due to friction among the
hour, minute and ALARM and/or
WORLD TIME hands.
Small amount of water/
blur inside of the glass
persists.
Water resistance is deteriorated.
The watch has been subjected to
water pressure that exceeds the
guaranteed degree.
Investigate the causes to take
necessary measures, while clean-
ing inside of the watch.
Remount the piezoelectric ele-
ment or replace it with a new
one.
Replace the stator with a new
one.
Adjust or remount the relevant
hands.
Symptom
Possible causes
Solutions
Exterior
parts
The step motor has been de -
formed.