GENERAL SAFETY INSTRUCTIONS (Cont.)

• If you notice any unusual odors or smoke around the unit, immediately disconnect the  
  unit from the outlet and contact the service center. Failure to do so may result in fire  
  or electric shock.
• When not using the unit for long periods of time or when you are moving the unit  
  please ensure to disconnect the power supply from the wall socket.
• Please beware that Dust could accumulate over time on the unit and cause it to generate  

  

heat and or deteriorate insulation, which in turn may result in an electrical fire.

• The product is not intended for use by persons (including children) with reduced physical,  
  sensory or mental capabilities, or young children of any age, They must be supervised  
  by a person responsible for their safety.
• Batteries from the remote control must be only removed by an adult, the adult must  
  ensure to keep them out of reach of infants and children. Seek medical attention  
  immediately if a child has swallowed a battery.
• To maintain the product do not use any chemical or cleaning agent or wet cloth, please  
  only ensure to utilize a dry cloth to wipe it down from marks or dust and only after  
  unplugging the product from the power socket.
• Always use the air con with the air filter mounted. Using it without the air filter can  
  cause accumulation of dust or waste on the inner parts of the device with possible  
  subsequent failters.
• Do not direct airflow directly onto plants or animals, as long exposure can affect them.
• Please ensure to contact our call center for any repair or service required for the products  
  not doing so will make warranty on your product void.
• We assume not liability for any eventual damages to property or injury to persons caused  
  by misuse of the product or noncompliance with these instructions.

Please make sure upon positioning this product, the place is:

• Not wet or damp and Well ventilated 
• Away from direct sunlight or heaters.
• Away from splashes or food.
• Protected from excessive dust or grease.
• Do not place containers with liquids, if liquid falls inside the products it may result in  
  short-circuit, fire or electric shock.
• Do not place small metallic objects on top of the unit or block the openings as it will  
  reduce operating efficiency of the air con with failures or damages.

PLEASE REFER TO THE INSTALLATION MANUAL ON SAFETY INSTRUCTION SPECIFIC TO 
EACH OF THE INDOOR AND OUTDOOR UNITS.

Содержание SC-6200AU6A

Страница 1: ...6 2kW AIR CONDITIONER SC 6200AU6A INSTRUCTION MANUAL Please read this manual carefully before using and keep it for future reference ...

Страница 2: ......

Страница 3: ... General Safety 4 Product Overview 6 Remote Control 7 Remote Control Use 8 Operations 9 Troubleshooting 12 Specifications 13 Customer Service 16 CONTENTS ...

Страница 4: ...uring operation of the equipment Do not bend twist or kink the power cord excessively Do not allow anything to rest on or roll over the power cord Doing so may cause a fire or an electric shock Do not run the power cord near heat producing appliances such as radiators stoves or irons The excessive heat could melt the insulation and expose live wires resulting in fire or electric shock Do not expos...

Страница 5: ...dry cloth to wipe it down from marks or dust and only after unplugging the product from the power socket Always use the air con with the air filter mounted Using it without the air filter can cause accumulation of dust or waste on the inner parts of the device with possible subsequent failters Do not direct airflow directly onto plants or animals as long exposure can affect them Please ensure to c...

Страница 6: ...6 PRODUCT OVERVIEW ...

Страница 7: ...7 REMOTE CONTROL ...

Страница 8: ... want LOW MED or HI will be symbolized by the number of blocks under the fan icon If you select AUTO the fan and block icons will flash Press the SWING button to choose the up down air flow direction you want NATURAL FLOW SWING or FIXED It will automatically be set to FIXED air flow direction in DRY mode Press the AIR FLOW button to choose the left right direction button you want SWING FIXED To be...

Страница 9: ...ce the timer has been set the digits shown on the screen will count down by 1 for each hour that has elapsed indicating the remaining time prior to the unit switching off Setting Turn On Time Set the time for the unit to turn on 1 While the air conditioner is in standby mode press the TIMER button and the airconditioner will go into timer switch on mode 2 Press the TIMER button again to set the de...

Страница 10: ...oors to heat the room air The heating capabilities through this principle of heat pumping alters with the variations of temperature of the outdoor air It will only take a short amount of time for hot air circulation to raise the room temperature If the temperature outdoors is extremely low this system can be used together with other heating devices as long as good ventilation is provided Defrostin...

Страница 11: ...up on the air filter screen and take it out in the direction of your body 2 Clean the air filter screen if dirty with lukewarm water and allow it to air dry 3 Reinstall the air filter screen Never use the unit without the filter in place 4 Regularly wipe the air conditioner clean with a soft dry cloth AFTER SEASON OPERATION 1 Set the temperature to 30 C and operate the unit in fan status for about...

Страница 12: ...12 TROUBLSHOOTING ...

Страница 13: ...ility 33 38 m Rated Voltage and Frequency 220 240V AC 50Hz Ingress Protection OUTDOOR UNIT IP24 Net Weight INDOOR UNIT 16 kg OUTDOOR UNIT 56 kg Max Pressure DISCHARGE 4 2 MPa SUCTION 1 3 MPa Refrigerant Type TYPE R410A QUANTITY 2150 g Noise Level INDOOR UNIT 42 48 dB A OUTDOOR UNIT 56 dB A Dimensions INDOOR UNIT mm 302 h x 1080 w x 220 d OUTDOOR UNIT mm 700 h x 870 w x 310 d ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...CUSTOMER HELPLINE 1300 296 699 DISTRIBUTED BY AYONZ PTY LTD ...

Отзывы: