9
IMPORTANT ADVICE
• The appliance must only ever be located and installed in a kitchen and not
any other room.
• Where you want to place the Cooktop, the wall and bench around the
appliance must be able to sustain temperatures of 95˚C. Laminates, surface
materials and fixing adhesives must be certified that it can sustain the
tempertures. Do not install the cooktop near curtains or flammable materials.
We assume no liability for any damage caused by this appliance if not
installed correctly as advised.
• Fire resistent surroundings (ceramic tiles for example) are required above the
cooktop of up to 450mm. Walls must be at least 200mm away from the burner.
There must be no overhanging surfaces, Rangehoods or exhaust systems must
not be within 750mm above the gas cooktop.
VENTILATION REQUIREMENTS
This Cooktop is to only be used in kitchens that have plenty of ventilation.
Using a Cooktop appliance produces heat and moisture in the kitchen in
which it is installed. Always make sure there is plenty of ventilation and keep
natural ventilation holes open or install a mechanical extractor hood.
For an extended intensive use of this appliance you will require additional
ventilation such as opening windows or raising the level of suction from a
mechanical extrator hood.
INSTALLATION (Cont.)
Содержание SC-600AUECT
Страница 2: ......
Страница 18: ...18 ...
Страница 19: ...19 ...
Страница 20: ...20 CUSTOMER HELPLINE info ayonz com DISTRIBUTED BY Ayonz Pty Ltd ...