Version Nr. 1-11 - 05.10.2022

Doc. No. 9985409576

3 / 24

Disregarding the instruction manual
Operating error
Inappropriate work on or with the unit
The use of non-specified spare parts and accessories
Unauthorised modifications or changes to the unit by the user or his personnel

The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main
contractual agreement. Claims for damages on any grounds are excluded.

3. Safety instructions

Upon delivery the unit is already meeting current technical standards and can therefore be safely taken into
operation. Only authorised personnel is allowed to work on the unit. Unauthorised personnel must be prohibited
from working on the unit. Operating personnel must inform their superiors immediately of any malfunction of
the unit. 
Please note that before starting to work on or with the unit, a procedure must be carried out inside the cabinet
on which the unit is to be mounted.
Before commencing work inside the cabinet, the control cabinet manufacturer's instruction must be read with
regards to:

Safety instructions.
Instructions on taking the cabinet out of operation.
Instructions on the prevention of unauthorised cabinet reconnection.

The electric equipment meets the valid safety regulations. One can find dangerous voltages (above 50 V AC or
above 100 V DC)

Behind the control cabinet doors.
On the power supply in the unit housing.

The unit has to be operated according to the type plate and the wiring diagram, and must be protected
externally from overloading and electrical faults via suitable protective devices.

Danger through incorrect work on the unit
The unit can only be installed and maintained by technical competent and qualified personnel,
using only supplied material according to the supplied instructions.
 

Danger from electrical voltage
Only specialised personnel are allowed to maintain and clean the unit. The personnel must
ensure that for the duration of the maintenance and cleaning, the unit is disconnected from
the electrical supply.
 
Attention
Damage to the unit through the use of inappropriate cleaning materials. Please do not use
aggressive cleaning material.
 
Instruction
Damage to the environment through unauthorised disposal. All spare parts and associated
material must be disposed according to the environmental laws.
 

Содержание 85409576

Страница 1: ...gs 4 5 Functional principle 5 6 Technical data 6 7 Performance graph 7 8 Mounting 8 9 Mounting Principle 11 10 Cut out dimensions 12 11 Electrical connection 13 12 Controller 15 13 Wiring diagram 19 1...

Страница 2: ...instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates e...

Страница 3: ...d with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid saf...

Страница 4: ...does not come into contact with the ambient air which may well be dirty or polluted Enclosure cooling units can dissipate large quantities of heat from sealed enclosures such as electrical enclosures...

Страница 5: ...refrigerant thus taking it to high pressure and high temperature and pushes it through the condenser where it is cooled by ambient air thus passing from the gas to the liquid state At the liquid state...

Страница 6: ...825 cfm Enclosure 441 706 cfm Mounting Wall mounted recessed Housing Material Mild steel powder coated Dimension H x W x D 1550 x 455 x 270 mm Weight 136 lbs Voltage Frequency 380 415 V 50 Hz 3 400 4...

Страница 7: ...Version Nr 1 11 05 10 2022 Doc No 9985409576 7 24 7 Performance graph...

Страница 8: ...internal and external are not obstructed It must also be ensured in accordance with UL that the air outlet is not blowing air directly at an equipment operator Should this be the case a barrier or du...

Страница 9: ...Nr 1 11 05 10 2022 Doc No 9985409576 9 24 Cold air outlet duct When using a cold air outlet duct please follow the steps below Filter installation If you install replace a lter please follow the step...

Страница 10: ...s The integrated condensate evaporation of the cooling unit releases the condensate to the environment If condensate formation is too great additional condensate can drip into an over ow trough which...

Страница 11: ...after installation Use only the supplied mounting hardware Tighten Screws to 4 5 Nm Ensure the mounting surface does not warp after assembly and reinforce it if necessary 1 M6 screws 2 M6 toothed wash...

Страница 12: ...Version Nr 1 11 05 10 2022 Doc No 9985409576 12 24 10 Cut out dimensions...

Страница 13: ...oller Setting temperature units C F low temperature alarm door contact logic section for more information c68 0 default ON if closed Door contact terminals bridged or NC door switch connected contact...

Страница 14: ...10 2022 Doc No 9985409576 14 24 Connect unit Connect the cooling device according to the instructions below The cable cross section must correspond to the required power for the current consumption bu...

Страница 15: ...ung aktiv 4 Relais Umgebungsl fter aktiv Alarm Blinkt wenn Alarm aktiv ist Heizmodus Zeigt an da das Ger t im Heizmodus ist K hlmodus Zeigt an da das Ger t im K hlmodus ist TEST Testmodus l uft Kann n...

Страница 16: ...raturalarm Grenzwert voreingestellt 10 C 14 F P26 f r Hochtemperaturalarm Grenzwert voreingestellt 55 C 131 F c68 f r T rkontakt NO NC Logik nderung 0 ON wenn geschlossen 1 ON wenn o en Steuerung Firm...

Страница 17: ...werden diese nacheinander angezeigt Fehlercode Beschreibung L sung OFF T r o en Schaltschrankt re schlie en ggfs T rkontaktschalter berpr fen Wenn kein T rkontaktschalter vorhanden und c68 0 T rkonta...

Страница 18: ...wird erscheint der Firmware Versionscode f r 2 Sekunden F r die Reinigung des Displays bitte nicht thylalkohol Kohlenwassersto e Benzin Ammoniak oder Derivate verwenden Es empfehlen sich Neutralreini...

Страница 19: ...Version Nr 1 11 05 10 2022 Doc No 9985409576 19 24 13 Wiring diagram Anschlu stecker 1 L1 2 3 N 4 PE Signalstecker 1 Alarm NO 2 Alarm COM 3 Alarm NC 4 T rkontakt 5 T rkontakt...

Страница 20: ...be protected with a MCB Type D or K Upon connection the internal fan will start working If the temperature inside the enclosure is higher than the set value of the controller both the compressor and e...

Страница 21: ...erant leakage Contact dealer service center Excessive condensate Enclosure door open Ambient air gets into the enclosure Ensure door is closed add a door switch and connect it to controller Enclosure...

Страница 22: ...temperature range 40 F to 158 F Relative humidity at 77 F max 95 The cooling unit should always be stored according to the installation position Returning the unit To avoid transport damage the unit...

Страница 23: ...Einstein Str 3 HF09 10 Wilerstrasse 16 B rnthal 1 Rep O ce 75 Circuit Drive 105 Lewis Road Hal Far Industrial Estate North Kingstown Wantirna South 42477 Radevormwald Birzebbuga BBG 3000 4563 Gerla ng...

Страница 24: ...05 10 2022 Doc No 9985409576 24 24 info de seifertsystems com info seifertsystems com info ch seifertsystems com info at seifertsystem com info seifertsystems com info us seifertsystems com info seife...

Отзывы: