13. Transport & Storage

Malfunction due to transport damage
On delivery the carton containing the unit must be examined for signs
of transport damage. Any transport damage to the carton could
indicate that the unit itself has been damaged in transit which in the
worst case could mean that the unit will not function.

Storage conditions

The unit can only be stored in locations which meet the following conditions:        

Temperature range: - 40°C to  + 70°C
Relative humidity (at 25°C): max. 95%

Returning the unit

Damage to the unit through incorrect transport.
To avoid transport damage the unit should be returned in the original
packing or in a packing case and must be strapped to a pallet!

If the unit cannot be returned in the original packing please ensure that:

A space of at least 30 mm. must be maintained at all points between the unit and the external packing.
The unit must be firmly fixed in the packing.
The unit must be protected sufficiently by shock absorbing padding (hard foam corner pieces, strips or
cardboard corner pieces).

14. Parts supplied

1 x Heat exchanger
1 x Instruction manual
1 x EC Declaration
1 x Power cable
1 x Brass connection ¼” with washer

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems AG

Seifert Systems Inc.

Seifert Systems Pty Ltd.

Albert - Einstein Str. 3

HF09/10 

Wilerstrasse 16

75 Circuit Drive

105 Lewis Road

 

Hal-Far Industrial Estate

 

North Kingstown

Wantirna South

42477 Radevormwald

Birzebbuga, BBG 3000

4563 Gerlafingen

RI 0285

3152 Victoria

Deutschland

Malta

Switzerland

USA

Australia

Tel.  +49 2195 68994-0

Tel. +356 2220 7000

Tel. +41 32 675 35 51

Tel. +1 401-294-6960

Tel. +61 3 98 01 19 06

Fax +49 2195 6899420

Fax +356 2165 2009

Fax +41 32 675 44 76

Fax +1 401-294-6963

Fax. +61 3 98 87 08 45

[email protected] [email protected] [email protected] [email protected] [email protected]

Содержание 5070048

Страница 1: ...egal regulations 2 3 Safety instructions 3 4 Technical functions 4 5 Functional principle 4 6 Technical data 5 7 Mounting 6 8 Electrical connection 7 9 Wiring diagram 8 10 Taking into operation 10 11...

Страница 2: ...e instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates...

Страница 3: ...with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid safe...

Страница 4: ...ies to external ambient air as the coolant In air to air heat exchangers the internal temperature of the control cabinet cannot be cooler than the ambient temperature There are natural limits to the c...

Страница 5: ...impeded Ambient air circuit 500 m h Cabinet air circuit 600 m h Mounting Internal Housing Material Aluminum Dimension H x W x D 1 010 x 465 x 150 mm Weight 21 kg Cut out dimensions 420 x 230 mm 420 x...

Страница 6: ...te thoroughness to ensure that the unit works perfectly Transport damage check On delivery the carton containing the unit must be examined for signs of transport damage Any transport damage to the car...

Страница 7: ...ion to the main electrical supply To connect the unit to the mains proceed as follows Take the control cabinet out of operation in the prescribed manner See the connection details on the circuit diagr...

Страница 8: ...ay actuated No relay function No relay function No relay function Location of alarms LEDs are tted in the fan controller assembly and visible from inside of customer enclosure T3 Internal air inlet te...

Страница 9: ...Version Nr 1 1 18 03 2020 Doc Nr 995070048 9 11...

Страница 10: ...aning must be carried out by specialists electricians The personnel must ensure that for the duration of this work the unit and the cabinet are disconnected from the electrical supply and protected ag...

Страница 11: ...d at all points between the unit and the external packing The unit must be rmly xed in the packing The unit must be protected su ciently by shock absorbing padding hard foam corner pieces strips or ca...

Отзывы: