Section 4: Flight Operations
Using the Firesock
2012 Bambi Max Operations Manual
(Version A)
10
Variable Fill Capability
In some areas, fire conditions require the reduction of bucket loads to accommodate weight restrictions
caused by high elevation operations.
The Bambi MAX has a gated valve system that allows the pilot to reduce the bucket load. By pressing and
releasing the dump switch as the bucket is being pulled from the water, the bucket weight can be reduced
until the desired load is reached as indicated by a load cell or torque gauge. As little as 2% can be shed in
this manner.
Using the Firesock
The Firesock, when attached to
the bottom of the Bambi MAX,
makes the bucket a more effec-
tive tool by increasing the aera-
tion of the foam when using a
Sacksafoam injection system.
The Firesock breaks down water
droplets (thereby increasing the
exposed surface area) when us-
ing straight water.
This simple design allows for im-
proved coverage and increased
drop accuracy as well as wider
and longer drop patterns.
To use your Firesock, simply attach the quick connect links onto the bottom chain and it’s ready for action.
When finished using it, make sure to:
•
Inspect the Firesock for damage and make repairs.
•
Clean the Firesock using fresh water.
•
Store the Firesock, attached to the Bambi MAX, ensuring both are dry.
Attaching a Firesock to a Bambi MAX.