Section 3: Using Accessories
Using the PowerFill System
2016 Bambi MAX Service Manual
–
Models 1518-3542
(Version E)
14
We Engineer Solutions
The pump is fully waterproof in operation to a depth of 10 ft. (3.0 m) and has a standard hydraulic grease
nipple provision to extend the life of the motor output shaft seal.
The mating flange consists of two plates that clamp together over the bucket shell to form a hard point for
quick mounting of the pump unit. The flange can be installed on a number of buckets to accept the same
pump unit. Mounted to the inside of the flange, a one-way flapper valve prevents water from flowing back
through the pump when the pump is not running. If the pump is not in use for a period of time, a blanking
plate should be installed to replace the pump.
The PowerFill Snorkel system comes complete with wiring harness. An optional control box can also be
ordered.
Flying with the PowerFill Snorkel System
No prior experience is required to quickly master using the PowerFill Snorkel since flying a Bambi MAX
with the PowerFill Snorkel will not adversely affect the flight characteristics of the bucket. To assist
operators with installation of the PowerFill Snorkel in an aircraft, this manual contains a suggested wiring
diagram.
Filling the Bambi Bucket with the PowerFill Snorkel System
Initiating a fill with the PowerFill Snorkel is simple and can be quickly mastered. Operation of the pump is
accomplished by simply pressing the fill button for as long as it takes to fill the bucket.
Important Note
If you are switching pumps from one size of bucket to another, it is recommended that the
discharge hose and restrainer chain also be changed to the lengths required for that bucket size.
MODEL Optimal Fill Time (Sec.)
BBX2024
30
BBX2226
33
BBX2732
41
BBX3542
53