4-3. UV Calibration
①
Go to UV Calibration mode.
Screen is changed as below and you can a message about Paper as below.
There are two kinds of UV Setting Paper as below.
If you have OLD UV setting paper, select [Paper] OLD first and go to next step.
If you have NEW UV setting paper, select [Paper] NEW and go to next step.
When touch
“PAPER” button, you can select OLD or NEW paper.
OLD UV setting paper
NEW UV setting paper
②
Press “LS1” Key (or click “SETUP” icon) and enter UV Calibration Mode.
And OFFSET SETUP is started automatically.
Содержание iH-110 Series
Страница 1: ...Rev 1 0 2 Date 2017 02 08 Cash counter Discriminator ...
Страница 20: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 20 9 Remove 2 screws as below ...
Страница 25: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 25 2 5 MODULE 2 ...
Страница 34: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 34 14 Open MODULE ...
Страница 39: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 39 7 Remove MAIN BOARD from the machine ...
Страница 56: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 56 6 Machine Setting Menu preparing ...
Страница 57: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 57 7 Engineer Setting Menu preparing ...
Страница 61: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 61 10 Trouble Shooting preparing ...
Страница 62: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 62 11 Block diagram ...
Страница 63: ...iH 110 Series Service Manual Hitachi Terminal Solutions Korea Co Ltd 63 ...