9. Product Maintenance
SMF-MP10S User guide V1.1 Shanghai Seer Intelligent Technology Corporation
59
9.2 Periodic Maintenance
S/N
Maintenance Content
Maintenance
Content
Criteria
Maintenance
Intervals
Frame Structure
1.1
Inspect whether the
nameplate is missing
and it is legible
Inspect visually
The information on
the nameplate shall
be legible
Every month;
replace or
contact with
the
manufacturer
1.2
Inspect for the damage
of the upper cover and
the outer surface of the
body
Inspect visually
Whether the normal
running of the robot
is influenced
Every month;
replace or
contact with
the
manufacturer
1.3
Inspect whether the
frame and bolt
connection are loose
Inspect visually
The marks of bolts
shall not be
misplaced.
Fasten
1.4
Inspect for the fork
damage and
deformation
Inspect visually
Whether the welds
are cracked
Every month;
replace or
contact with
the
manufacturer
Electrical System
2.1
Inspect the functions of
operating switches,
display devices and
photoelectric switches
Power on and start
the robot for test
The function shall
be normal
Every month,
troubleshoot or
contact with
the
manufacturer
for assistance
2.2
Inspect the function of
emergency stop button
Power on and start
the robot for test
The function shall
be normal
Every week,
troubleshoot or
contact with
the
manufacturer
for assistance
2.3
Inspect the function of
the driving lights
Power on and start
the robot for test
The function shall
be normal
Every week,
troubleshoot or
contact with
the
manufacturer
for assistance
2.4
Inspect the function of
anti-collision bumper
Collision test: Turn
on the robot
The function shall
be normal
Every month,
troubleshoot or