Burner
Injector size (mm)
Nat Gas
Propane
Gas rate (MJ/h)
Nat Gas
Propane
SUPER
SIMMER
Inner
Outer
WOK
Inner
Outer
LARGE BOILER
0.50
0.25
5.9
5.9
1.00
0.60
1.50
0.90
11.0
11.0
0.65
0.50
18.0
18.0
1.90
1.05
A
N
E
Brown
Blue
Blue
Green/yellow
Spark electrodes
(1 to each burner)
Ignition switch under each control knob.
Depressing any knob initiates spark to ALL
burners simultaneously.
Blue
240Vac 50Hz
supply
Servicing must be carried out by qualified personnel only.
Do not modify this appliance.
Wiring Diagram - Electronic Ignition Models Only
Component access
1
Disconnect electricity supply.
2
Remove trivets, burners, spillbowls
and knobs.
3
Gently lift glass or stainless steel hob
upwards to gain access to all internal
components.
Servicing
1
Refer
Troubleshooting
section of this
manual.
2
If parts require cleaning, refer
Cleaning Instructions
section of this
manual.
3
If parts require replacement, replace
with only genuine Tudor spare parts.
4
For spare parts call 1300 367 437.
11
SEELEY INTERNATIONAL
– OWNER’S & INSTALLATION MANUAL
SERVICING INSTRUCTIONS AND
SPECIFICATIONS
Specifications