Testing and Commisioning
Check For Gas Leaks
1
Check the gas line for leaks - rectify
any leaks found.
Check Gas Test Point Pressure
Natural Gas models
1
The gas pressure test point is located
on the outlet side of the regulator.
2
Remove the test point screw and
connect a suitable manometer to the
pressure test point.
3
Light all burners.
4
Check that the pressure is 1.0 kPa -
adjust the regulator if required.
5
If you cannot achieve the specified
pressure, check the gas supply line.
The cooktop requires a minimum
supply pressure of 1.13 kPa at the
inlet of the regulator.
6
Once the pressure is set correctly,
lock the regulator adjusting screw,
remove the manometer and replace
the test point screw.
7
Re-light at least one burner and
re-check for leaks at the pressure
test point.
Check Gas Test Point Pressure
Propane models
1
The gas pressure test point is
located on the gas inlet pipe
supplied.
2
Remove the test point screw and
connect a suitable manometer to
the pressure test point.
3
Light all burners.
4
Check that the pressure is 2.75 kPa.
5
If you cannot achieve the specified
pressure, check the gas supply line.
6
Remove the manometer and replace
the test point screw.
7
Re-light at least one burner and
re-check for leaks at the pressure test
point.
Check operation and
instruct customer
1
Check that ignition to all burners
operates correctly.
2
Check that flames are even on all
burners.
3
Check that controls operate correctly
between marked "HI" and "LO"
positions.
4
Hand instruction manual to
customer/home owner and explain
operation.
10