    BREEZAIR TBQ/TBS OWNER’S MANUAL  

|  

3

 

OPERATING YOUR COOLER

To provide efficient cooling or ventilation 

 

the building must have sufficient exhaust 

openings to the outside of the building.  

To assist air flow, open windows and doors that 

are farthest from the outlet vent in each room. 

In these rooms, provide an exhaust opening 

about 2 times the vent size of the room. 
Where the design of the building prevents 

adequate exhaust, consideration should 

be given to the provision of mechanical 

extractions, such as an exhaust fan. 
There are three main ways that an evaporative 

cooler can operate to provide cooling comfort.  
The cooler can be set at a constant fan speed, 

without reference to the current temperature. 
•  The cooler can be given a temperature 

target, in which case it will vary the fan 

speed in order to get as close to the 

target as possible. (Note! Humid weather 

conditions may limit what temperatures  

can be achieved.)

•  The cooler can be set to a fan only mode, 

providing air circulation only.

Hello and congratulations 

on purchasing a Breezair 

evaporative cooler for your 

home.

At Seeley International we manufacture 

Breezair evaporative coolers from the highest 

quality materials, and we have designed the 

product to provide many years of economical, 

trouble-free cooling.

MAGIQTOUCH CONTROLLER SETTINGS 

MENU

Your MagIQtouch Controller contains  

a settings menu which gives you access  

to information about your Breezair evaporative 

cooler and to extra functions including: 

ABOUT APPLIANCE

Access information about the appliances 

installed in your system.

MIN/MAX SET TEMPERATURE

You can change the minimum and maximum 

temperature displayed on your slider, 

depending on what temperature range  

you prefer your system to work within.

NIGHT QUIET MODE

Restrict fan speed over the night time period 

for a quiet night’s sleep.

MANUAL DRAIN

This will turn the cooler off and drain the tank.

PAD FLUSH

This will turn the cooler off and run the pumps 

for a specified time. Use this feature to flush 

the cooler pads or in the event of a bushfire.

DRAIN AND DRY

This option allows you to nominate a time each 

day when the cooler will drain the tank and run 

the fan for 1 hour.

AUTOCLEAN

Select the preferred cleaning interval (50 / 100 

/ 200 hrs). At 8.00am after the selected running 

hours has been reached, the cooler will drain 

the tank, fill with fresh water and operate the 

pump for 5 minutes. When complete, drains 

the tank and returns to previous operation 

mode. 

Note!

 There are some settings that are just for 

trained service agents or installers. You won’t 

be able to access any of these options without 

a pin code.

Содержание Breezair TBQ

Страница 1: ...OWNER S MANUAL TBQ TBS Evaporative Cooler English Original English Instructions ...

Страница 2: ......

Страница 3: ...up and operate this system This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance...

Страница 4: ... DRY 3 AUTOCLEAN 3 WATER MANAGEMENT 4 WATERMANAGER 4 DRAIN VALVE 4 CONTINUOUS BLEED SYSTEM 4 POWER OUTAGES 4 HEALTH REGULATIONS 4 MAINTENANCE 5 PRE SEASON 5 END OF SEASON 5 COOLERS WITH DRAIN VALVES 6 COOLER ISOLATION SWITCH 6 WATER DISTRIBUTION CHANNELS 6 REMOVING THE BLEED SYSTEM 6 HIGH DUTY CYCLE OPERATION MAINTENANCE 7 MAINTENANCE SCHEDULE SERVICE CHECKLIST 8 TROUBLESHOOTING 9 ...

Страница 5: ...d the product to provide many years of economical trouble free cooling MAGIQTOUCH CONTROLLER SETTINGS MENU Your MagIQtouch Controller contains a settings menu which gives you access to information about your Breezair evaporative cooler and to extra functions including ABOUT APPLIANCE Access information about the appliances installed in your system MIN MAX SET TEMPERATURE You can change the minimum...

Страница 6: ...vel reaches a preset level the WaterManager will open the drain valve and release saline water Fresh water will then be added diluting any minerals or salts accumulated The WaterManager will continue to monitor and drain water as required Alternatively the cooler can be set to drain saline water at a preset period of pump operating time This can be set by changing the salinity control method selec...

Страница 7: ...e pad frames Ensure power is off at isolating switch inside the cooler Gently wash pad frames to remove any dust build up during winter IMPORTANT Do not damage the pads with high pressure water spray Inspect pad retention pins and washers for damage and that they are securely fitted Replace the bleed system if it was removed during previous maintenance and ensure the O ring is fitted If the cooler...

Страница 8: ...towards you until the internal side clips disengage Pivot the pad frame outwards and lift up Take care not to damage the pad ILL1001 C REMOVING THE BLEED SYSTEM Unclip and remove the bleed system as shown SEASONAL MAINTENANCE cont REMOVING PAD FRAMES Insert a flat screw driver tip into the slot as shown and lever until disengagement occurs ...

Страница 9: ...continuously throughout the year the following maintenance program is required 6 monthly maintenance Inspect the cooler and check the pump drain valve if fitted solenoid and fan motor Check the pads and replace as required Check and clean the tank and the pump filter 12 monthly maintenance Replace plastic fan and motor collet and check motor shaft for wear ...

Страница 10: ...rvoir Pump Filter Water Probes System Washers Seals and O Rings replace as required Drain Valve Bleed System Operation Component Function Pump Operation Drain Valve Operation Motor Operation reset motor amps where required Solenoid Operation Wall Control Operation General Operation Water Level Set Point Water Fill Time Water Drain Time Water Distribution across Pads Airflow through system Outlets ...

Страница 11: ...ooling Dry pads Ensure the water supply is turned on Then check the water flow to the pads Insufficient exhaust openings for conditioned air Ensure sufficient exhaust openings Excessive ambient humidity On days during the summer when the ambient humidity is high the cooler will not reduce the temperature as much as on drier days Cooler turns ON and OFF Fault in the cooler Contact the Dealer or Ser...

Страница 12: ...ications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected MANUFACTURED BY SEELEY INTERNATIONAL PTY LTD 112 O SULLIVAN BEACH RD LONSDALE SA 5160 AUSTRALIA IMPORTED BY SEELEY INTERNATIONAL EUROPE LTD 5 PAPPLEWICK LANE HUCKNALL NOTTINGHAM NOTTINGHAMSHIRE NG15 7TN UNITED KINGDOM SEELEY INTERNATIONAL AMERICAS LTD 1202 NORTH 54TH AV...

Отзывы: