background image

5

Timed automatic start

Timed automatic stop

You can set the air cooler so that it will turn on
after a set number of hours.

1. To set the delayed start time, press

with the cooler turned OFF. “Starting in” will
be displayed as shown with the last mode of
operation (Manual or Automatic).

2. If you want the air cooler to turn on in

Automatic mode with the previous settings,
then press

until “Auto” is displayed.

Alternatively, if you want the air cooler to
turn on in Manual mode, press

until

“Man” is displayed and then press
and then S or T to set the required fan
speed.

3. To set the time until the start, press

.

4. Then press S or T to adjust the time.

The cooler can start up to 24 hours in
advance.

5. Press

again to initiate the timed

automatic start. The timed start will not
repeat.

You can also set the air cooler so that it will turn
off after a set number of hours.

1. To set a delayed stop time, press

with the cooler running. ”Stopping in” will
display.

TIMER

AUTO

AUTO

COOL

TIMER

TIMER

TIMER

2. Press S or T to adjust the number of

hours before the air cooler will stop. The
maximum delay setting is 24 hours.

3. Press

again to begin the timed stop.

TIMER

SEELEY INTERNATIONAL –

OWNER’S MANUAL

®

CPL LCB BM Evaporative Cooler

®

6

Using the cooler

Now that you have read these instructions, press
the

button to turn your air cooler on. If

the air cooler has not operated for a while, “Pre
Cool Cycle” will flash on the display. The “Pre
Cool Cycle will begin and will take only a few
minutes to complete. After this time, the fan will
come on automatically, and you can enjoy the
comfort of cool fresh air!

POWER

Air too cold

With the cooler running in Automatic mode, you
may find that you are too cold or that the air
cooler is blowing too much air. Press T to
lower the automatic temperature setting and
reduce the amount of cooling.
If you are too cold with the cooler running in
Manual mode, then press T to reduce the fan
speed. You can also circulate fresh un-cooled air
by pressing

until “Vent” displays.

COOL

Air not cold enough

You may find that with the air cooler running in
Automatic mode, you are not cool enough.
Simply press S to increase the cooling rate.
If you are not cool enough with the air cooler
running in Manual mode, then press S to
increase the fan speed. Ensure that cooled air is
circulating by pressing

until “Cool”

displays.

COOL

You can experiment with the settings on your
wall control. This is the best way to get the
most from your air cooler.

WALL CONTROL FUNCTIONS -

cont.

WALL CONTROL FUNCTIONS -

cont.

This cooler comes with a continuous bleed
system (Coolair CPL, Braemar BM) or automatic
Drain Valve (standard for Braemar LCB, optional
for Coolair CPL and Braemar BM).

During operation, the bleed system will drain
small amounts of water. This ensures fresh water
is continually added to dilute salt accumulation in
the water caused through evaporation. This
helps keep the air cooler in good condition and
ensure optimum performance. The bleed rate will
depend on local operating conditions and will be
set by the installer.

If the drain valve was installed instead of the
continuous bleed system then your cooler will
automatically drain periodically. This ensures the
water is always fresh and helps maintain your
cooler in good condition to ensure optimum
cooling performance. The frequency of the
automatic drain may have been adjusted by your
installer according to the general water quality in
your area.
When the cooler is turned off for 72 hours, the
drain valve will open automatically and empty
water from the cooler. When the cooler is turned
on again, fan operation will delay for a few
minutes while the tank refills and the cooling
pads are saturated again.
At any time when the thermostat is OFF, you can
drain the cooler by pressing and holding S
and T for 1 second. The display will show “dr”
to confirm the operation has activated.

Continuous bleed system

Automatic drain valve

DRAIN VALVE & BLEED SYSTEM

ILL1478-A

Содержание BM1150

Страница 1: ...ILL1456 A English LCB CPL BM OWNER S MANUAL Evaporative Cooler ...

Страница 2: ... 1 CPL LCB BM Evaporative Cooler Introduction Wall Control Functions Drain Valve Bleed System Maintenance Service Checklist Troubleshooting 7 9 6 3 2 10 ...

Страница 3: ... for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Effective cooling To provide efficient cooling or ventilation t...

Страница 4: ...eration it was in when last turned off If your air cooler has not been operated for a while then when you start it Pre Cool Cycle may sometimes flash on the display as shown This indicates that the water pump will operate to saturate the cooling pads for a few minutes before the fan is turned on This is to ensure that when the fan starts only cool air enters the building WALL CONTROL FUNCTIONS CPL...

Страница 5: ...the cooler turns off Press S or T to overide the automatic cooling level setting and adjust your room temperature To switch to Manual mode press AUTO until Man appears in the display In Manual mode the cooling level can be manually adjusted In Manual mode press to choose between circulating cool air or un cooled air When Cool is displayed fresh cool air will circulate into the building When Vent i...

Страница 6: ... and then press and then S or T to set the required fan speed 3 To set the time until the start press 4 Then press S or T to adjust the time The cooler can start up to 24 hours in advance 5 Press again to initiate the timed automatic start The timed start will not repeat You can also set the air cooler so that it will turn off after a set number of hours 1 To set a delayed stop time press with the...

Страница 7: ...ur air cooler WALL CONTROL FUNCTIONS cont This cooler comes with a continuous bleed system Coolair CPL Braemar BM or automatic Drain Valve standard for Braemar LCB optional for Coolair CPL and Braemar BM During operation the bleed system will drain small amounts of water This ensures fresh water is continually added to dilute salt accumulation in the water caused through evaporation This helps kee...

Страница 8: ...e is required However we require that the following components and the operation thereof be checked after the first year then every 2 years as routine maintenance 1 Pump 2 Drain Valve 3 Solenoid and associated filter 4 Fan motor operation and current 5 Float valve Routine maintenance may be required more frequently in adverse environmental situations or where the appliance is installed in non dome...

Страница 9: ...peat external inspections as per End of Season Service Remove the pad frames as shown Ensure the power switch in the cooler is off Gently wash the pads to remove any dust build up during the winter period If the pads are in poor condition replace them Inspect pad retention pins and washers for damage and that they are securely fitted Replace the bleed system if it was removed during previous maint...

Страница 10: ...s seals and O rings replace as required Drain operation Bleed rate set where required Pump operation Drain valve operation Motor operation set motor amps where required Solenoid operation Wall control operation Water level set point Water fill time Water drain time Water distribution across pads no dry spots Airflow through system outlets General product condition Service No Service Date Service T...

Страница 11: ...nt openings Refer to chart on Pg 2 3 Excessive ambient humidity See also Insufficient exhaust On days where the ambient humidity is high the cooler will not reduce the temperature as much as on drier days If your wall control displays SERVICE or should you consider that your cooler requires service contact your local Dealer or the Service number on the back of this manual Note If on initial start ...

Страница 12: ... improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected When you contact your Dealer regarding service or warranty please quote the cooler model number and serial number as shown below Warranty Service Australia 1 300 650 644 seeleyinternational com ...

Отзывы: