background image

 

 

Precaution and Safety Guidelines 

 

Thank you for purchasing our product.   

 
Please  read  this  manual  carefully  and  fully  understand  the  portions  of  the 

installation and operation instructions prior to installing and using the product. 
 

Should  you  have  any  part  of  them  not  understandable  or  if  you  have  any 
problem during your installation or in using it, please contact us. 

 

Reproduction of this instruction or any part thereof without permission is strictly 
prohibited. 

You must read the precautions required for safe operation prior to using it and 
operate it correctly.   

 

Please  understand  that  the  contents  of  this  operating  instruction  may  differ 
slightly  due  to  functional  improvement  of  a  product  and  based  on  the 

specification chosen by the user.   
You can use this product easier and more conveniently if you use the function of 

the product only after reading this operating instruction carefully.   

 

 

 

 

 

 

 

CAUTION 

 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN 

 

 

CAUTION :   
TO  REDUCE  THE  RISK  OF  ELECTRIC  SHOCK,  DO  NOT 

REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. 
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. 

 

 

The  lightning  flash  with  arrowhead  symbol  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 

presence  of  uninsulated  “dangerous  voltage”  within  the 
product’s enclosure that may be of sufficient magnitude to 

constitute a risk of electric shock to persons. 

 
The  exclamation  point  within  an  equilateral  triangle  is 

intended  to  alert  the  user  to  the  presence  of  important 
operating and maintenance (servicing) instructions in the 

literature accompanying the product. 

 

 

  

 

WARNING: To reduce the risk of fire or electric shock, do not expose this 

apparatus to rain or moisture. 

 

 

Содержание SC-VCD0001A

Страница 1: ...VIDEO DATA TRANSMISSION OVER SINGLE COAX CABLE SC VCD0001A SC VTD0001A SC VRD0001A User s Manual SC VTD0001A SC VRD0001A ...

Страница 2: ...sen by the user You can use this product easier and more conveniently if you use the function of the product only after reading this operating instruction carefully CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol withi...

Страница 3: ... directional data communication Bi directional Input and Output of alarm signals via separated alarm In Out port Long distance transmission up to MAX 1km with RG 6 Saving infrastructure cost Built in distance level switch for optimum video quality Installation improvement cost saving 25 30 Maintaining high quality video interference immunity Easy installation with BNC harness Surge lighting protec...

Страница 4: ... indicator Green it flickers when it transmits the data Yellow it turns on when the power is on and it flickers when it receives the data Power input both 12VDC and 24VAC input are available Please note that there is no in the power input port Notes Please do not connect in parallel the RS 485 terminals of the transmitter SC VTD0001A Please use one transmitter for each receiver The alarm signal is...

Страница 5: ... ON ON Auto detect None ON ON ON Resistance of the Termination Mode SW No 4 Disconnected Default OFF Connected 120 OHM ON Notes Please turn the power OFF after changing the switch SW and then turn it ON The auto detection is available with 1200 2400 4800 9600 only The size of packet should be lower than 21 bite 2P Terminal Block connect the power adapter 24VAC 12VDC 4P Terminal Block 2P for alarm ...

Страница 6: ...ⅹ 60 H ⅹ 25 D 7 Precautions Please turn the power OFF prior to the installation of the device The data error can be occurred where the installation circumstances are harsh enough such as the higher voltage container belts etc Do not install or use these units in a humid hot or hazardous explosive environment without suitable and adequate protection Do no expose these units to magnetic materials hi...

Страница 7: ... we give you free repair service according to the warranty certificate We charge you with the fee of parts and service despite of free warranty service period Any breakage made without care such as Breakage or trouble made by natural disaster Breakage or trouble made by breaking the product guide or manual Breakage or trouble made by wrong power voltage or frequency When you want to reassemble for...

Страница 8: ...0 06 6 S Su un ni il l T Te ec ch hn no op pi ia a 4 44 40 0 S Sa an ng gd da ae ew wo on n D Do on ng g J Ju un ng gw wo on n G Gu u S Su un ng gn na am m S Si i G Gy ye eo on ng gg gi i D Do o K Ko or re ea a T TE EL L 8 82 2 0 0 3 31 1 7 77 77 7 3 35 50 08 8 F FA AX X 8 82 2 0 0 3 31 1 7 77 77 7 3 35 51 12 2 E EM MA AI IL L o ov ve er rs se ea as s s ss sc cc ct tv v c co om m h ht tt tp p w ww...

Отзывы: