INSTALLATION MANUAL AND USERS GUIDE 

Multi Split Series – Ductless Split – Cassette Indoor unit 

 

 

04006020101 

© Sedna Aire Europe GmbH 

10/2012 

 

2.  REMOTE CONTROL DESCRIPTION AND MANUAL  

Actual remote control may vary, but functionality remains

 

 

 

 
 

Turns unit on and off 

Adjusts Temperature setting: (not in 
Auto mode) 
+ to increase temperature, hold 2 sec. 
for fast change 
- to decrease temperature 

Change operation mode:  
press the mode button until you see the 
desired mode 
- Auto, sets automatically 
- Cool 

 

- Dry 

 

- Fan  

  

- Heat  

 

“I Feel” Enhanced Comfort:  
Press the button to switch this function 
on or off: Then the temperature sensor 
in the remote control and not in the wall 
unit will master the control. 

Air Function:  
Press to turn on or off 

 

Swing Function: Press to set up&down swing 
angle of air guide louvers. Various static 
angles or a dynamic oscillating angle of the 
louver may be chosen: The first sign on the 
upper left row indicates the oscillating mode, 
while the others install a static angle. 

 

24 Hour timer: Switch TIMER ON/TIMER OFF 
on or off. After pressing   disappears and 
“ON” blinks. 00:00 is displayed. Press within 5 
sec. “+” or “-“ to set time. Every press changes 
time by 1 min. Holding down the “+” “-“ buttons 
rapidly changes the time setting by 1 min. and 
then 10 min. After having set, press TIMER-
ON/TIMER OFF within 5 sec. to confirm your 
input 

Display light on/off: Switch display light on/off 

Displays set temperature, room temperature or 
outdoor temperature. The temperature control 
range for the indoor unit is 16°C to 30°C. 

10 

“One Touch” sleep function: Press to set the 
unit to sleeping mode or wake it up again (in 
Cool, Dry, Heat mode) 

11 

Turbo Fan  
Press the button to cool or heat faster  

12 

Indoor fan delay: Press to set a fan delay ( ) 
of  10 min. after you have turned off unit in 
order to dry unit (only COOL& DRY mode) 

13 

Clock setting - to set current time 
When pressed once, the clock setting mode 
appears and   blinks. Same logic as for the 
timer setting. After having set, confirm your 
choice by pressing “CLOCK” and then   will 
be constantly displayed  

14 

Plasma Ion Generator (if available) 
Press the button to switch on or off 

15 

Adjustable 3-speed fan 
Press the button and “+” or “-“ to increase or 
decrease the desired fan speed

 

Lock: Press “+” and “-“ simultaneously to lock or 
unlock. If locked,    is displayed. When you press 
any button,    blinks 3 times 
°F 

 °C: Switch unit off and press simultaneously 

MODE and “-“  

Содержание CM Multi Split Series

Страница 1: ...aight forward applications where more than one indoor unit are needed The new CM Series of Sedna Aire heat pumps offers outstanding performance as well as environmental protection These models with their high efficient compressors in DC Inverter technology offer when matched with our SolarcoolTM panel efficiency rates 2 3 times better than current comparables best in class systems EER 8 for Coolin...

Страница 2: ... 8 8 Care and maintenance 9 9 Trouble shooting 11 10 Location of installation 13 11 Dimensions of cassette unit 14 12 Installation of indoor cassette unit 15 13 Electrical wiring 18 14 Installation of front cover panel 18 15 Checks and test run 20 16 Warranty 20 IMPORTANT The installation and especially the connection between the outdoor unit and the Solarpanel shall be only performed by trained a...

Страница 3: ... CASSETTE Composing parts System overlook Air intake Air Outlet Remote Control Drain hose Zoom in Display Timer Compressor Operation Timer Comp Oper Drainage equipment for discharging condensate water from indoor unit when cooling Drainage hose Guide louver placed in air outlet vent Connecting pipe Air inlet grille Air outlet vent Air filter purifier in air inlet grille ...

Страница 4: ... attempt to repair the air conditioner by yourself Wrong repair may cause an electric shock and may kill you Don t apply cold wind over longer time on you It may cause a cold and harm your health especially over night when you sleep If your detect unusual phenomenons like smell or burning smoke turn off immediately the unit It may cause damage electrical shocks and impact your health Don t place a...

Страница 5: ...running the unit It can decrease the air conditioning capacity Don t blow the air directly to and plants It may impact their health when not properly controlled Don t damage the power and signal cords Don t damage or cut the cords If this has happened contact service center or other trained and skilled electricians since wrong repairs may kill you Don t splash water on the indoor units It can caus...

Страница 6: ...s displayed Press within 5 sec or to set time Every press changes time by 1 min Holding down the buttons rapidly changes the time setting by 1 min and then 10 min After having set press TIMER ON TIMER OFF within 5 sec to confirm your input 8 Display light on off Switch display light on off 9 Displays set temperature room temperature or outdoor temperature The temperature control range for the indo...

Страница 7: ... The breakers act as short circuit prevention and to avoid abnormal overloads The main switch must be accessible easily and at all times Switch of power before cleaning and maintenance of the indoor units After having turned off the indoor units they will continue to work for 20 70 sec to deplete the residual cool heat in the unit s evaporator while preparing for next operation This is normal When...

Страница 8: ...t will be removed after the unit has stopped This is intended to avoid mildew in the indoor unit When having set X FAN on After turning off the unit On Off button the fan in the indoor unit will continue for further 10 min If you want to stop that too press X FAN again When having set X FAN off After turning off the unit On Off button the unit will stop at once Auto Run In the AUTO mode the unit w...

Страница 9: ... panel is dirty please use a cloth which is slightly moistened with warm water cleanser under 40 C then dry it and wipe off the dirty spots NOTE The indoor units contains microcomputer components and circuit board in the display which are very sensitive against water So don t put any water into the interior of the indoor unit Clean the air filters in the indoor unit at least all 6 months recommend...

Страница 10: ...rifier out Install new filters in frame and reinsert purifiers in the air filter Reinsert the filter Fix the purifiers on the filter install filter on the several bulges on top of the grille Pull the handle behind the grille toward inside to fix the filter Close the air inlet grill analogue to step 1 Repetitive maintenance of indoor unit Turn power off Clean air inlet grill Clean air inlet filter ...

Страница 11: ...ing running or the air conditioner is stopped sometimes you may hear hua hua or di du di du noise This is the flowing sound of refrigerant other than fault Sometimes a thin fog will flow out of the outlet when air conditioner is running in cooling mode This might occur when indoor temperature and humidity are high This is because the indoor air is quickly cooled down After a period of time the fog...

Страница 12: ...ut under heating or defrost auto defrost mode Under cooling mode water attached on heat exchanger will drip No air blows out from indoor unit When the temperature of indoor heat exchanger is low during heating process the indoor unit will stop air blowing to prevent blowing of cold air within 3 minutes In HEAT mode when outdoor temperature is low or humidity is high and much frost on the heat exch...

Страница 13: ... have access for routine maintenance e g replacing the filters The height of the installation should be min 1 8 m above the floor Install cassette in middle of the room to allow optimal air distribution into all corners Stay away at least 1m from other electric appliances like TV audio devices etc Do not locate the indoor unit in the immediate proximity of a laundry bath shower or swimming pool Ma...

Страница 14: ... GmbH 14 10 2012 11 DIMENSIONS OF CASSETTE UNIT CMC12 CMC18 CMC24 The decorated covers of the cassette shall overlap the ceiling by min 20 mm 950 Cover of cassette 890 Ceiling opening 840 Indoor unit 680 780 950 Cover of cassette 890 Ceiling opening 840 Indoor unit Refrigerant pipe Hoisting screw 650 570 400 570 604 650 ...

Страница 15: ... and lower nut gasket on rod Check helping installation cardboard with openings in ceiling Central mark of the ceiling opening is marked on the cardboard Install helping installation cardboard on unit Hang the unit onto the desired location using the rods and gaskets IMPORTANT Check if the unit is horizontal if not turn nuts until unit is horizontal If the unit is not horizontal water may leak sin...

Страница 16: ...ck the connection for leakage Use water soap solution Insulate gas pipes and their connection to prevent condensation and water leaks by covering provided insulation sheet completely around the connection and nut Fasten the isolation sheet against tear off NOTE PLEASE FOLLOW THIS INSTUCTION OTHER WISE CONDENSATE DEVELOPS DROPS AND DAMAGES THE CEILING Install drain pipe hose During cooling condensa...

Страница 17: ...e ceiling at a distance of 1 1 5 m by using the clamps Insert the hose into the clamp and tighten the clamp Isolate the drain hose against the clamp Isolate the hose AND the surrounding clamp against condensation When you install more cassettes connect the drain hose serial from the highest to the lowest that always a negative slope downwards exists Drain hose Drain hose Clamp Ceiling Correct Wron...

Страница 18: ...f the terminal board connect the Signal wire to the 2 terminal and connect the L wire to the 3 terminal and connect the earthing wire to the earth terminal Earthing MUST be done If not it may harm and kill the user Fix the cable with the clamp the section of power cable with protective pipe into pressing groove and close the cover plate Tighten the fixing screws to clamp the connecting cable Put t...

Страница 19: ...ling material 3 Screw the 4 hexagonal head screws under the latches about 15mm in The panel rises 4 Adjust the panel by turning it along the arrows shown below so that it closes all gaps 5 Tighten the screws until the sealing material between panel and indoor unit is 5 8 mm thick Make sure no gaps between ceiling and cover panel occur They are critical and can deteriorate much the cooling capacity...

Страница 20: ... Model Serial No Owner s phone Owner s email Owner s signature Dealer s name Installer s name Installer s address Installer s signature stamp Limited warranty by Sedna Aire Europe Valid is the warranty claim as published on the Homepage of Sedna Aire Europe at the time of purchase date Sedna Aire hereby warrants to the consumer that all units are free from defects in materials and workmanship and ...