Dome Functions 
 

<OTHER> 

 
PARK MODE: After an idle period of time has elapsed which is set in 

the next parameter (Park Time), the camera will perform the 
action which is selected here. The options are: NONE, Pattern 1, 
Tour 1, 360 Scan, A/B Scan or Presets 1 thru 8. 

 
PARK TIME: This is the amount of time (in minutes) which the 

camera will wait after receiving the last manual PTZ command. 
After this time has elapsed, the camera will perform the function 
set in the PARK MODE parameter above. 

 
 
NOTE: 

The alarms functions are not supported on this model of 

camera. Although the alarm menu can be accessed and settings 
can be made, they will have no effect on the camera, as there 
are no physical alarm inputs or outputs.

 

 
 
 

<IR> 

 
IR MODE: This sets how the IR LEDs are enabled.  AUTO is the 

default setting. Auto allows the camera to operate the IR LEDs 
as lighting conditions need it, in conjunction with the 
ILLUMINATION ON and IR SWITCH ZOOM settings as 
described below. 

 
OUTPUT POWER: This determines the maximum brightness of the 

LEDs when they are on. Power can be set from 1 thru 9. 

 
TESTING TIME: This determines how long the ambient light level 

must remain below the ILLUMINATION ON threshold before the 
camera will switch to IR mode. Choose from 2 to 15 seconds. 

 
STANDBY POWER: Allows the user to set a lower-power usage level 

for the IR LEDs which engages when the camera sits idle for the 
time which is set in the STANDBY TIME parameter below. 
Choose from power levels 1 thru 9. 

 
STANDBY TIME: This is how long (in seconds) the camera must sit 

idle before switching the IR LEDs into STANDBY POWER 
mode, as set above. 

 
ILLUMINATION ON: This setting determines at what ambient light 

level the IR LEDs will turn on and the camera will switch to night 
mode. When the IR mode is set to AUTO, this setting determines 
the brightness level at which the camera will switch from day to 
night and vice versa. 

 
IR SWITCH ZOOM: This determines the lens zoom level at which the 

camera will change the IR LEDs from “close-up” lighting mode to 
“distance” lighting mode. 

 
 

<OTHER> 

 

PARK MODE                    NONE 
PARK TIME                             05 
POWER ON ACT        MEMORY 
RATIO SPEED                      ON 
AUTO FLIP                            ON 
 
EXIT 

<IR> 

 

IR MODE                        AUTO 
OUTPUT POWER                  9 
TESTING TIME                  08s 
STANDBY POWER               8 
STANDBY TIME                20s 
ILLUMINATION ON           05L 
IR SWITCH ZOOM              07 
AMBIENT LIGHT                 06 
 
EXIT 

Содержание ST-PTZMINI-IR10X

Страница 1: ...1 INSTALLATION MANUAL ST PTZMINI IR10X High Speed Intelligent Dome Software Addressable IR PTZ Color Camera ...

Страница 2: ...call Supported Protocols Pelco D P 4 patterns Each pattern can record 512 different PTZ instructions or roughly 600 seconds of PTZ path operation Proportional control speed When zoomed to full telephoto mode a low pan speed of 0 02 s provides smooth panning 4 Tour groups The dwell time and position of 16 preset points per tour can be edited independently Built in high precision real time clock sup...

Страница 3: ...ervicing is required when the device has been damaged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 11 Do not use this product under circumstances exceeding specified temperature and humidity ratings 12 Avoid pointing the camera directly to the sun or ot...

Страница 4: ...Preset Speed 200 s Programmable Tours 4 groups Points Per Tour Max 16 points dwell time user selectable Pattern Scan 4 patterns Pattern Scan Record max 512 commands Roughly 10 minutes Park Time 1 60 minutes available PWR on Action Memory Pattern Tour 360 scan A B scan Preset 1 8 None Park Action Pattern Tour 360 scan A B scan Preset 1 8 None Communication Protocol Pelco D Pelco P Communication RS4...

Страница 5: ...5 Product Dimensions in millimeters Bracket Dimensions Included Wall Mount Bracket Optional Ceiling Mount Bracket ...

Страница 6: ... Installation Connections Before connecting please turn off the power of all connected devices Use the included power supply to ensure the camera is being supplied sufficient current for proper operation ...

Страница 7: ... now complete The camera is now initializing and detecting the module of camera The display now indicates that ST 370 is the specific model of camera module which is installed This is displayed after the camera finishes detection Self testing is now complete IR SPEED DOME PROTOCOL PELCO D P COMM 2400 N 8 1 DOME ID 001 MODULE VERSION V1 2 PAN INIT TILT INIT POWER ON IR SPEED DOME PROTOCOL PELCO D P...

Страница 8: ...OCUS NEAR and FOCUS FAR controls will temporarily override the AUTO FOCUS function As soon as any PTZ command is received the camera will revert back to AUTO FOCUS Preset Point This camera will respond to all standard Pelco preset commands Please refer to your PTZ controller or DVR instruction manual for specific instructions regarding how to set call and clear preset points NOTE Some preset point...

Страница 9: ...isplays the current coordinates of the camera IR Display means the IR display status is on means the IR is on Remark means the cursor selecting some option means editing the content of some options NOTE The default communication settings for this camera are BAUD 2400 ADDRESS 1 and PROTOCOL PELCO D CAUTION THERE ARE NO DIP SWITCHES IN THE CAMERA DO NOT OPEN THE CAMERA CASING FOR ANY REASON DOING SO...

Страница 10: ...10 OSD Menu ...

Страница 11: ...OSD COMM SET menu The choices are 1200 2400 4800 and 9600 DOME ID This displays the dome s address The range is 000 255 The address is changed via the OSD COMM SET menu MODULE This displays the model of the CCD camera module VERSION The software version may be periodically updated as newer versions become available COMM SET DEVICE ID This is an ID number which is unique to each individual unit of ...

Страница 12: ...the camera rather than this method which uses the camera s OSD menu Dome Functions SCAN SCAN SPEED The scan speed can be set to values from 1 thru 9 The speed set on this page will affect Left Right scans and 360 scans NOTE The effective range of Left Right scans is a minimum of 20 between points and a maximum of 340 between points Dome Functions GUARD TOUR The camera can store 4 tours each contai...

Страница 13: ... to 512 individual PTZ commands roughly 10 minutes PATTERN NO First select the pattern 1 thru 4 to be set up or called CALL PATTERN If a pattern has been previously recorded selecting this option will call the pattern number shown above and the camera will begin playing back the recorded pattern The pattern will play in a loop until any PTZ command is received by the camera PATTERN Selecting this ...

Страница 14: ...e on Power can be set from 1 thru 9 TESTING TIME This determines how long the ambient light level must remain below the ILLUMINATION ON threshold before the camera will switch to IR mode Choose from 2 to 15 seconds STANDBY POWER Allows the user to set a lower power usage level for the IR LEDs which engages when the camera sits idle for the time which is set in the STANDBY TIME parameter below Choo...

Страница 15: ...hen a preset or tour is called or when the camera reaches the Left and Right limits of an A B scan etc TIME Set this to ON to display the dome s internal clock time or OFF to prevent display of the time IR When set to ON the illumination level of the IR LEDs will be displayed in the top left corner of the screen Time TIME DATE Allows the user to set the system date for the camera TIME Allows the u...

Страница 16: ...mera is English and cannot be changed Reset RESET CAM DATA This setting is not applicable to this model of camera The menu will allow the user to proceed as if camera module initialization is taking place but the procedure will have no effect on the camera settings SYS DATA Using this function will reset all system data and memory in the camera and return the camera to its factory default settings...

Страница 17: ...rescent lamps in the vicinity d The picture appears smeared i The power supply voltage level may be unstable Try another power supply ii Ensure the cables are correctly connected and of the right impedance e Other interference may require the use of a SecurityTronix ground loop isolation filter f Power is on but the controller does not work i Check to make sure the DIP switches are all set correct...

Отзывы: