14
4 OSD Menu
4.1 Menu Index
Страница 1: ...INSTALLATION MANUAL ST PTZIR650 23 High Speed Intelligent Dome PTZ Color Camera ...
Страница 2: ...L SYMBOLS The lighting flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to different persons The exclamation point within an equilateral triangle is intended to alert the user the presence of important opera...
Страница 3: ...f the video camera to Avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera All electrical connections to the dome should be made in strict accordance with the attached labels and wiring instructions in this manual and in accordance with all local and national electrical codes Failure to do so may damage the dome beyond repair and void the warranty ...
Страница 4: ...tyTronix service personnel Servicing is required when the device has been damaged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 11 Do not use this product under circumstances exceeding specified temperature and humidity ratings 12 Avoid pointing the came...
Страница 5: ...2 1 Product Contents IR Speed dome 1pc Wall mount bracket 1pc Power supply 1pc Screws kit 1pc User manual 1pc ...
Страница 6: ...15 minutes or 512 commands Home Pos Time 1 60mins available PWR on Action Memory as power off Pattern 360 scan A B scan Preset cruise Preset 1 8 No action Communication Protocol Pelco D Pelco P Communication RS485 Bus Baud Rate 1200 2400 4800 9600bps Privacy Mask Not supported on this module 3D Location supported Time Scheduling function Not supported on this module Alarm Optional Auto tracking Op...
Страница 7: ...ity RTC clock supports time management function Strong video processing ability supports auto tracking and motion detecting alarm function Park action If the user does not operate the dome in a predetermined time it will automatically run a preset guard group trace memory group pan scan etc The dome can remember its current operation before being powered off and return to its previous operation af...
Страница 8: ...amera s zero point When the dome is in use preset drift can occur over time If this happens the zero point can be used as a reference for the dome to reset its alignment Auto Flip In the manual tracking mode when a target goes directly beneath the dome the dome will automatically rotate 180 degree in horizontal direction to maintain continuity of tracking When the dome flips the camera starts movi...
Страница 9: ...n that the pitch angle remains the same While scanning the operator can move the joystick to exit from the scanning mode Preset Once the camera has been programmed with specific location presets it can automatically move to the predefined positions when presets are called from a PTZ controller or DVR Guard Tour Scan The dome runs a patrol according to the specific presets which the user has progra...
Страница 10: ...een menu rather than the DIP switches See page 11 for details 2 1 2 Address Settings DIP switch SW1 is used to set the address of the camera It is an 8 bit switch The number value of switch 1 1 switch 2 2 switch 3 4 switch 4 8 switch 5 16 switch 6 32 switch 7 64 and switch 8 128 The values of all switches which are in the ON position are added to determine the address See illustration below As an ...
Страница 11: ...itch of FUN SW2 is to select the matching resistor In order to prevent interference of the RS 485 communication signal and other signals the parallel matching resistor is needed in the communication interface of the dome camera at the far end of the RS485 bus run Use the 8th switch of the FUN switch group to connect the resistor the the RS485 bus ONLY IF THE CAMERA IS THE LAST CAMERA ON THE BUS If...
Страница 12: ...9 2 2 Bracket Dimensions 2 2 1 Included Wall Mounted Bracket 2 2 2 Optional Corner Mounted Bracket ...
Страница 13: ...r be used with an electrical box or mounted to a stud indoors The wall must be able to bear at least 4 times the weight of the dome To install the wall hanging bracket a As shown in fig 2 use the installation holes of the wall hanging bracket as a pattern and mark the locations of the holes on the wall Fig 2 b As shown in fig 3 attach the wall hanging bracket to the wall with wire and cable passed...
Страница 14: ...struction 3 1 Power Up Action When initializing the system the OSD screen shown at left will appear after 2 seconds When restoring the original factory settings please wait patiently The restore process takes roughly 1 minute to run Continued on next page IR SPEED DOME PROTOCOL PELCO D P COMM 2400 N 8 1 DOME ID 001 MODULE VERSION PAN INIT TILT INIT POWER ON ...
Страница 15: ... Press ZOOM button to zoom in for a narrower field of view for distant objects Focus Press FOCUS button to manually focus the camera on distant objects Press FOCUS button to manually focus the camera on close objects Iris Manual IRIS control is not supported on this camera module IR SPEED DOME PROTOCOL PELCO D P COMM 2400 N 8 1 DOME ID 001 MODULE VERSION PAN OVER TILT OVER POWER ON IR SPEED DOME P...
Страница 16: ... confirm Left Return to main menu or cancel Zoom Display Format x XXX XXX shows the present zoom of camera Time DisplayFormat XXXX year XX month XX day XX hour XX minute XX second Angle Display Format XXX XX pan XXX XX tilt IR Display means the IR is turned on means the IR output power PREST FUNCTION PRESET FUNCTION 33 Pan scan180 º 86 BLC on 34 Reset 87 BLC off 75 Call Pattern 1 88 Freeze on 76 C...
Страница 17: ...14 4 OSD Menu 4 1 Menu Index ...
Страница 18: ...into this field to enable address changes for just this camera TARGET ID Enter the new address you wish to assign to this camera It will be effective immediately after it is changed PASSWORD SET PASSWORD 1 Enter the password PASSWORD 2 Re enter the password 4 2 Dome Set 4 2 1 Preset PRESET NO Select the preset number to be SET or CALLED CALL PRESET Calls the preset number selected above SET PRESET...
Страница 19: ...re the 16 steps available for the tour Each step will call 1 preset POINT The preset for each step Any preset from 1 thru 64 can be assigned to a step TIME The default time of all points is 05s The range is 05 60s SPEED The speed between two points in each guard tour group can be set individually The range is 1 64 Note Preset 33 and 34 can t be set as guard tour point 4 2 4 Pattern SCAN SCAN SPEED...
Страница 20: ...y pressing the right key 2 Press the up and down keys in the keyboard to edit the mask number which is be entered by pressing the right key means selecting this mode while hourglass symbol means editing this mode 3 Move the cursor to SET MASK and press right key to set the position of privacy zone See the figure on the left below 4 Move the joystick to aim at the object Use the ZONE WIDE and ZONE ...
Страница 21: ...le ALARM MODE Mode has on an off selectable PRIOR Prior has none and 1 4 level selectable ALARM IN Alarm in has low input and high input selectable ALARM ACT When prior is none alarm action preset point 1 8 selectable when prior is 1 4 level alarm action has pattern guard tour 360 scan preset scan and preset point 1 8 selectable ALARM OUT Alarm out has nc and no selectable DWELL TIME Time has 0 59...
Страница 22: ...tc TIME Displays the current time on screen IR indicates that the IR LEDs are lit The status can be seen at the top left corner of the screen The IR display progress bar will be filled gradually along with the illumination level TEMP Display the inside temperature of the dome 4 6 Time Set DATE Set the system date TIME Set the system time SCHEDULE Action Choose preset 1 8 A B scan 360 scan guard to...
Страница 23: ...g the schedule 4 7 Language LANGUAGE Language has English Spanish French Germany Italian Polish and Portuguese Russian etc selectable 4 8 Reset RESET CAMERA This is used to initialize the camera back to the factory default settings This applies to the camera module only not to presets tours etc DEFAULT This is used to initialize the system settings including the camera settings but it will not del...
Страница 24: ...In strong thunderstorm areas or areas with high induced voltage such as high voltage substations installation of additional high power lightning protection equipment and lightning rod is essential Lightning protection and grounding of outdoor devices and lines must take the lightning protection requirements of buildings into consideration and comply with the related national standards and industry...
Страница 25: ... communication bus with a typical impedance of 120Ω whose maximum load capacity is 32 payloads including the master device and the controlled device 2 Mode of Connection and Terminal Resistance 2 1 The RS485 bus requires that parallel connections should be used between the devices with 120Ω terminal resistances connected at the both ends Fig 26 Fig 27 2 2 120Ω terminal resistance is connected as s...
Страница 26: ... ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OF...
Страница 27: ...F ON OFF OFF OFF OFF 12 ON ON OFF ON OFF OFF OFF OFF 13 OFF OFF ON ON OFF OFF OFF OFF 14 ON OFF ON ON OFF OFF OFF OFF 15 OFF ON ON ON OFF OFF OFF OFF 16 ON ON ON ON OFF OFF OFF OFF 17 OFF OFF OFF OFF ON OFF OFF OFF 18 ON OFF OFF OFF ON OFF OFF OFF 19 OFF ON OFF OFF ON OFF OFF OFF 20 ON ON OFF OFF ON OFF OFF OFF 21 OFF OFF ON OFF ON OFF OFF OFF 22 ON OFF ON OFF ON OFF OFF OFF 23 OFF ON ON OFF ON OF...
Страница 28: ...orescent lamps in the vicinity d The picture appears smeared i The power supply voltage level may be unstable Try another power supply ii Ensure the cables are correctly connected and of the right impedance e Other interference may require the use of a SecurityTronix ground loop isolation filter f Power is on but the controller does not work i Check to make sure the DIP switches are all set correc...