ST-POE24M
Hardware Installation Manual
- 12 -
4
Data transmitting
TXD
Output
5
Transmission
requesting
RTS
No connect
6
Response transmitting
CTS
No connect
7
Data terminal ready
DTR
No connect
8
Signal ground
SG
GND
Note:
The console port of the
ST
-POE24M switch does not support traffic control. Therefore,
you must set the option
data traffic control
to
none
when you configure the switch
with the super terminal.
Otherwise, the single-pass problem will arise on the super terminal. The cable is used
to connect the console port of the
ST
-POE24M switch and the outside console terminal
device. One end of the cable is a 8-pin RJ45 plug and the other end is a 9-hole plug
(DB9). The RJ45 plug is put into the socket of the console port on the
ST
-
POE24M switch. The inner line connection in the cable is shown in figure 3-1. The
console cable is numbered as RLC0301.
Figure 3-5 Cable connection at the console port
3.3.2
Connecting Fast-Ethernet Interface
The
ST
-POE24M switch has 24 10/100Base-TX ports. The indicators are in the
right side of the front panel of the switch, indicating the LINK/ACT state. You can
connect other Ethernet terminal devices to the UTP port through a straight through
or cross network cable. The numbering order of the pins in the UTP port is the
same as the console port.