5. TROUBLESHOOTING
a. No picture after applying power – (i) check all plugs and cables are securely
connected to the proper connectors; (ii) ensure your power supply is providing the
correct voltage and current.
b. The picture has ripples – (i) check to see if the power supply is experiencing AC ripple, if
so a filter may be required; (ii) determine if the monitor is faulty; (iii) determine if other
peripheral equipment is causing ripple and if so make the necessary adjustments.
c. The picture background continuously changes color – a fluorescent lamp’s magnetic
field may cause color roll, therefore, reduce the number of fluorescent lamps or
increase the distance between the camera and the lamps.
d. The picture appears smeared – (i) the power supply voltage level may be unstable,
therefore, try another power supply; (ii) ensure the cables are correctly connected
and/or the cables are of the correct impedance.
e. Other interference may require a Securitytronix ground loop isolation filter.
f. Additional troubleshooting assistance can be found on-line at
in
addition to support from Securitytronix technicians at
1-800-688-9282
, option
3
, then
option
2
.
v1.0 8/4/14