different frequency letters, please be guided by the project documentation. When
using more than five sensors on the object, check their applicability by the trial
operation.
2. When installing the sensors in ways other than those given in the present
manual, check their applicability by the trial operation.
2.3.2
Installation order
2.3.2.1
Ensure compliance with requirements of item 2.1.2.
2.3.2.2
Prepare the perimeter to install the posts.
2.3.2.3
Install the posts. As posts it is recommended to use metal pipes with a diameter of
70…90 mm. The height of the post above the ground should be at least 1100 mm. In
areas with much snow, the above-ground part of the post should be at least 1500 mm.
2.3.2.4
Installation of posts in concrete is possible. The posts are made of steel pipe with a
diameter of 76 mm and may have a length of 2 m or 2,5 m. The post construction
contains a rebar to hold the post in concrete and holes to enter the cable.
2.3.2.5
The above-ground part of the post should be at least 1100 mm.
Figure 2.1 shows an installation of posts.