2.2.1.4
When cabling, terminating and connecting the cable to the sensor, the power supply
should be switched OFF.
2.2.1.5
The sensor is powered with 10…30 V DC or with 220 V AC through the power supply
unit. Before starting works, please learn the user manual of the power supply unit.
2.2.1.6
Persons who have been specially instructed and have passed a safety test are allowed
to install, maintain and repair the sensors.
2.2.2
Rules for unpacking and inspecting the sensor.
2.2.2.1
Before unpacking the sensor, carefully inspect the package and ensure its integrity.
Before opening the package, check the presence of the stamp of the quality
department.
2.2.2.2
The package should be opened indoors or under a canopy. When unpacking, avoid
ingress of precipitation and influence of aggressive substances on the sensor.
2.2.2.3
Check the completeness of the sensor.
2.2.2.4
Check the presence of the quality department stamp in the passport of the sensor.
2.2.2.5
The sensors should be free from defects like deep scratches and dents.
2.3
Installation and configuration
2.3.1
General guidelines
2.3.1.1
The sensors should be installed in accordance with requirements of the present manual
and projects recommendations on the alarm system.
2.3.1.2
The sequence of installation works is based on convenience of their execution.
2.3.1.3
The sensors should be installed to provide a convenient supply of connecting cables
and free access to them during mounting, operation and maintenance.
2.3.1.4
The sensor wiring and connection to the junction box and power supply unit are to
perform in accordance with the project for the alarm system.
ATTENTION!
1. DON`T INSTALL THE SENSORS NEXT TO EACH OTHER, IF THEY
HAVE THE SAME FREQUENCY LETTER. When ordering the sensors with