5
This ID setup switch shows 10010011 corresponding to ID148. Each camera ID setting and
OSD are entered as below:
Switch Position
1
2
3
4
5
6
7
8
OSD
CAM
Selection
O
FF
O
FF
O
FF
O
FF
O
FF
O
FF
O
FF
O
FF
001
CAM-001
O
N
O
FF
O
FF
O
FF
O
FF
O
FF
O
FF
O
FF
002
CAM-002
O
FF
O
N
O
FF
O
FF
O
FF
O
FF
O
FF
O
FF
003
CAM-003
O
FF
O
N
O
N
O
N
O
N
O
N
O
N
O
N
255
CAM-255
Other ID numbers can be setup according to the Address Code
Correspondence Table at the end of the
manual.
5. Communication Protocol Setting
The #3 & #4 positions of SW2 on PCB are used for setting the communication protocol as below
Switch
Position
3
4
Protocol
OFF
OFF
State Standard
OFF
ON
PELCO-D
ON
OFF
PELCO-P
6. Baud Ratio Setting
The #5 & #6 positions of SW2 on the PCB are used for setting baud ratio as below
Switch
Position
5
6
Baud Ratio
OFF
OFF
1200 bps
OFF
ON
2400 bps
ON
OFF
4800 bps
ON
ON
9600 bps
Содержание SLC-171C