13
Refractory replacement
The intense heat of the fire will normally cause hairline cracks in the refractory. These cracks can
be minimized by proper curing as described in "First fires". They will not normally diminish the
effectiveness of the refractory. If large cracks develop, then the refractory should be replaced. To
replace the refractory bricks, follow these steps:
1.
Remove the bottom refractory
2.
Remove the left side refractory
3.
Remove the right side refractory
4.
Remove the back refractory
5.
Remove the front baffle refractory
6.
Remove the rear baffle refractory
To install the new refractories, follow the above steps
in reverse.
Doors installation
The doors must be installed only when the
installation of the BIS ULTRA is completed.
All you have to do is fit the male part of the
hinge, already fixed on the doors, in the
female part, which is already fixed on the
fireplace.
To remove the doors, simply pull up the doors from the
hinges.
The doors adjustment has been set at the
factory. If the fit is still not perfect, you can
adjust the doors using the hinge screws (see
fig.4).
Figure 2
Figure 3
Содержание BIS ULTRA EPA
Страница 5: ...5 CERTIFICATION LABEL ...
Страница 17: ...17 INSULATED CHASE CONSTRUCTION Figure 11 ...
Страница 26: ...26 AIR COOLED GALVALUME CHIMNEY Figure 28 NOTE THE OUTSIDE AIR KIT IS MANDATORY ...
Страница 29: ...29 Table 4 ...