8
XR40 User’s Guide
Introduction
Introduction
XR40 User’s Guide
9
Entry or Exit Zone
Almost all systems have one or more doors through which you can
enter or exit the premises. These doors are programmed with a
delay time to allow you to enter or exit while the system is armed
without setting off the alarm.
When you arm the system, activity on all burglary zones is ignored
until the programmed exit delay time expires. Once that time has
expired and the system is fully armed, opening the door causes the
panel to start the entry delay time.
Instant Zone
Exterior windows and non-entry doors, or interior protection
devices, are typically not programmed with delay times. If these
zones fault while the system is armed, an alarm occurs instantly.
24-Hour Zone
A 24-hour zone is not turned on or off by arming or disarming your
system. Some examples of 24-hour zones are fire zones, panic
zones, and temperature control zones.
Areas
An area is made up of burglary zones that can be armed or
disarmed together. The Perimeter area, for example, consists of
all the doors and windows on the outside of the building. When you
arm the Perimeter, these zones sound an alarm if tripped.
Central Station Monitoring
Your system can also be programmed to automatically send alarm,
trouble, and arming and disarming reports to a central station.
Operators at the central station can then dispatch the appropriate
authorities or contact you with the specific event information.
Status
Status is a feature that automatically displays the system armed
or disarmed status on the keypads. Alarm or trouble conditions
on a zone or a system monitor such as AC or battery trouble can
also display. There are two types of status information available:
Status List
and
Armed Status
.
Status List
The keypad Status List displays any alarm or trouble condition on
a zone and any trouble condition that occurs with the AC power or
battery power. If your system contains any Panic zones, these do
not display on the keypad for security reasons.
If an alarm occurs on a non-fire, 24-hour zone or a system monitor,
it remains in the Status List until it restores. If one or more armed
burglary zones trips, the last one to trip remains in the Status List.
The burglary zone alarm remains in the Status List for several
minutes or until it is cleared by disarming the system.
Armed Status
With Armed Status, the keypad displays the current armed condition
of areas within your security system.
The keypad displays
When
HOME MODE ON
The perimeter areas is armed in a
Home/Away system.
PERIMETER ON
The perimeter is armed in an All/
Perimeter system.
ALL SYSTEM ON
All areas are on.
SLEEP MODE ON
The perimeter and interior areas are on
but the bedroom area is off.
Also, for keypads that include an Armed LED, the Armed LED is ON
steady anytime a burglary protection area is armed and OFF when
ALL areas are disarmed.
Содержание XR40
Страница 1: ...User s Guide XR40 ...
Страница 51: ... This page intentionally left blank ...
Страница 52: ...LT 0494 12 06 ...