34
XR200-485B User’s Guide Supplement
This supplement is intended for use with the XR200-485B Access
Control Interface Card and includes information about the
additional features specific to the 485B.
Two Man Rule
During an entry delay time, the keypad displays
ENTER CODE:
. If
areas of your system are programmed for Two Man Rule, anytime
a user enters a code to disarm a Two Man area or perform a door
access, the keypad displays
2ND CODE: -
for 10 seconds. A second
and different user code must be entered within that 10-second
period. If you enter a second code that is the same as the first code,
the keypad displays
INVALID CODE.
If you enter a second code that
does not have the equivalent authorization as the first code, the
keypad displays
TRY AGAIN.
If you do not enter the second code
within the 10-second period, the display returns to normal.
Early Morning Ambush
If your system is programmed for Early Morning Ambush, when an
area is disarmed by a user code, an Ambush message will be sent to
the central station unless you enter a second user code. This
message is delayed by a programmed number of minutes to allow
time for you to inspect the premises for intruders. (See the System
Setup on the next page for the amount of time programmed for the
Early Morning Ambush delay.) The second user code can be the
same code or a different code entered from the Status List in the
disarm menu. If the second user code is not entered before the
Early Morning Ambush delay expires, a silent Ambush message is
sent to the central station. The second user code must have
authority to cancel the Early Morning Ambush operation.
System and Panic Zones Test
System Test is used to test the system including battery, alarm bell
or siren, and communication to a central station. Also, system test
is used to test user panic zones. This allows you to test panic
buttons for operation without sending a message to the central
station. The System Test or Panic Zone Test function begins
automatically as soon as you select it.
Using the System Test
1. Access the User Menu.
2. Press COMMAND until
SYSTEM TEST?
displays.
3. Press any Select key. The keypad displays
SYSTEM PANICS.
4. Press the Select key below
SYSTEM
.
5. The System Test begins automatically. The keypad displays:
a)
BELL SOUNDING
during a two second bell test
b)
BATTERY - OKAY
or
BATTERY - TRBL
to indicate the
condition of the battery
* c)
TRANSMIT TEST
and
ATTEMPT NO : 1
during the
transmit test
d)
TRANSMIT OKAY
or
TRANSMIT FAILED
to show the
results of the transmit test
e)
TEST END
to indicate the System Test is complete.
f) You can end the transmit test by pressing the Back Arrow key.
* The transmit test does not operate on local systems.
XR200-485B User’s Guide Supplement