XR200-485 Arming/Disarming
9
System Arming
Area Assignment:
Your security system has been set up into
separate areas. The number of areas and their names are listed
in the back of this guide.
Arming or Disarming:
You can arm and disarm all areas at one time
or each area individually. You can only arm or disarm areas
authorized for your user code.
Arm all or Selective Arming:
After entering your user code, the
system allows you to arm either all of the areas to which you have
access or one or more selected areas. If you choose to arm all areas,
the system begins verifying that all zones in those areas are in a good
condition. If you choose to arm selected areas, the system prompts
you to choose the areas you want to arm.
Arming the System
1. Press the COMMAND key until
ARM DISARM
is displayed.
2. Select
ARM
to arm the system.
3. Enter your user code if required. The display reads
ALL? NO YES
.
4. Select
NO
to arm only selected areas. Go to step 5. Select
YES
to arm all areas authorized for your user code. Go to step 6.
5. If you selected
NO
in step 4, the display begins to list each area
to which you have access followed by
NO
YES
.
Example:
OFFICE NO
YES
5a. Select
YES
for each area you want to arm.
5b. Select
NO
for each area you do not want to arm.
Note:
You can also just press the area numbers you want to arm
while at the
ALL? NO YES
display. This changes the display
to
AREAS:
. The area numbers you select appear in the
display. For example:
AREAS: 2 4
. Press COMMAND when
done.
6. The system displays any bypassed zones or faulted 24-hour or
Priority zones. A faulted Priority zone cannot be armed.
7. At this point you can
force arm
or
bypass
any faulted zones. A
zone that is force armed will be restored into the system if it later
returns to normal. A zone that is bypassed will remain bypassed
until the system is disarmed. See steps 7a through 7d.
7a. If a problem exists on a zone, the zone name and problem
is shown followed by:
OKAY BYPASS STOP
.
7b. Select
OKAY
to force arm the faulted zone.
7c. Select
BYPASS
to bypass all faulted zones being displayed.
Note
: 24-hour zones cannot be bypassed.
7d. Select
STOP
to stop the system from arming. Correct the
zone problem(s) and return to step 1.
Your system may be programmed to require a user code that
has authorization to force arm or bypass a faulted zone. The
system will ask for a user code to be entered.
8. The display reads
SYSTEM ON
if at least one area in the system
is armed, and
ALL SYSTEM ON
if all areas in the system are
armed.
9. The keypad then displays the exit time in seconds and counts
down the remaining time:
EXIT : ##
(
##
= seconds remaining).
The exit zones arm when the delay time expires.
Содержание XR200-485