Security Command 670 Скачать руководство пользователя страница 1

1

2

3

4

5

6

7

8

9

0

COMMAND

A B C

DEF

GHI

JKL

VWX

STU

PQR

MNO

YZ

POWER

    User's Guide

Содержание 670

Страница 1: ...1 2 3 4 5 6 7 8 9 0 COMMAND A B C DEF GHI JKL VWX STU PQR MNO YZ POWER User s Guide ...

Страница 2: ... temporarily If possible they will notify you in advance but if advance notice is not practical you will notified as soon as possible You will be informed of your right to file a complaint with the FCC FCC Information Supplied to Users Your telephone company may make changes in its facili ties equipment operations orproceduresthatcouldaffect theproperfunctioningofyourequipment Iftheydo youwill ben...

Страница 3: ...keys 3 Terms 4 Status 5 Closing Check Extend 6 System Arming and Disarming For Area System 7 Area System Arming 8 Area System Disarming 9 System Arming and Disarming For All Permieter 10 All Perimeter Arming 11 All Perimeter Disarming 12 TABLE OF CONTENTS Model 670 770 771 Security Command User s Guide For use with DMP Series 1512 Controls Copyright 1992 1993 Digital Monitoring Products Incorporat...

Страница 4: ...tion this message will be displayed INVALID TIME This message is displayed when a level 1 or 2 code number is entered outside permanent or temporary schedules Level 1 or 2 codes will function only during a permanent or temporary schedule This message is displayed when there is an electronic failure in your alarm system You should contact your alarm dealer if this message is ever displayed Special ...

Страница 5: ...ing information such as a code number If an error is made while entering information press the back arrow and the character will be erased The back arrow will also back up a step in the operation of any Menu Option If the back arrow is pressed at the first step in a Menu Option the option will terminate This is a quick way to exit a Menu Option when you are finished with it The back arrow will not...

Страница 6: ...run from your alarm control cabinet to each protection point in your alarm Therefore each door window motion detector smoke detector etc which has been individually wired to the alarm control cabinet via a loop ofwireisreferredtoasaloop Sinceeveryloopcanhaveanameandnumber the SECURITY COMMAND can use these to identify a protection point for you Like loop 3 Front Door or loop 12 Smoke Detector Entr...

Страница 7: ...CURITY COMMAND SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND will stay in Status until you choose to go to system arming disarming or a menu option Armed Status Armed Status will display the current armed condition of your burglary system in one of two ways If this is an area arming system the area number is displayed if the area is armed Examples Both areas are armed 1 2 Are...

Страница 8: ...sarmed Extending A Schedule Extending A Schedule Extending A Schedule Extending A Schedule Extending A Schedule is accomplished by pressing a top row key to silence the closing time display After a valid code number is accepted the keypad will request thenew closingtime Anytimemaybeenteredupto11 59p m Ifnotimeisentered the closing time will be extended for one hour Step by Step Step by Step Step b...

Страница 9: ... check to see that all doors and windows which will be armed are closed and that any motion detectors etc are set properly SYSTEM ARMING AND DISARMING FOR AN AREA SYSTEM If no problems exist the areas you have selected will be armed If a problem does exist on one or more loops the SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND will display the problems and all...

Страница 10: ...r to arming and bad 24 hour loops will be displayed No action is required by you 7 Bypass any bad loops if required step 7a 7b 7c 7a If a problem exists on one or more loops the loop name and problem will be displayed followed by BYPASS NO YES BYPASS NO YES BYPASS NO YES BYPASS NO YES BYPASS NO YES NO 7b Select to stop the arming sequence without bypassing any loops Correct the problem and return ...

Страница 11: ...ion problems which occurred during the armed period All burglary loops in the areas you selected are then disarmed and any bypassed loops are automatically reset Disarmed Message Disarmed Message Disarmed Message Disarmed Message Disarmed Message After disarming the SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND will display ALL SYSTEM OFF if all areas are now...

Страница 12: ...OMMAND SECURITY COMMAND SECURITY COMMAND SECURITY COMMAND will display the problems and allow you to bypass those loops If the problem can be corrected by simply closing a door or window you should not bypass You should correct the problems and repeat the arming procedure If the loop or loops are in some way damaged and cannot be corrected they may be bypassed Bypassing a loop means it will be ign...

Страница 13: ...YES BYPASS NO YES NO 5b Select to stop the arming sequence without bypassing any loops Correct the problem and return to step 1 YES Select to bypass all non 24 hour loops displayed as bad 5c Enter your code number if required to bypass loops 6 The display will read SYSTEM ON SYSTEM ON SYSTEM ON SYSTEM ON SYSTEM ON if only the perimeter is armed and ALL SYSTEM ON ALL SYSTEM ON ALL SYSTEM ON ALL SYS...

Страница 14: ...RITY COMMAND will display any loops which tripped or any transmission problems which occurred during the armed period All burglary loops are then disarmed and any bypassed loops are automatically reset Central Station Report Central Station Report Central Station Report Central Station Report Central Station Report A report of the system disarming can be transmitted to your Central Station This is...

Страница 15: ...ser Code Level User Code Level User Code Level 1 During permanent or temporary schedules only 3 Anytime Function Function Function Function Function Resets smoke detectors Fire Reset is used to reset smoke detectors after they have been tripped Once a smokedetectorhasbeentrippeditmustberesetbeforeitwillfunctionagain When Fire Reset is selected the smoke detectors are automatically reset Insure tha...

Страница 16: ...turn on for five seconds DoorAccessalsofunctionsanytimeanyareaofthesystemisdisarmedatthedoor strike keypad or by simply entering your code number and pressing COMMAND A report of this entry can be transmitted to your central station This report is optional and is programmed during system installation Step By Step Step By Step Step By Step Step By Step Step By Step 1 Press the key until DOOR ACCESS...

Страница 17: ...med will be displayed with area number and name Step By Step Step By Step Step By Step Step By Step Step By Step 1 Press the key until ARMED AREAS ARMED AREAS ARMED AREAS ARMED AREAS ARMED AREAS is displayed 2 When ARMED AREAS ARMED AREAS ARMED AREAS ARMED AREAS ARMED AREAS is displayed press any one of the top four select keys The display will list each armed area one at a time 3 If no areas are ...

Страница 18: ...cnumberthentheloopname and status will be displayed Step By Step Step By Step Step By Step Step By Step Step By Step 1 Press the keyuntil LOOPSTATUS LOOPSTATUS LOOPSTATUS LOOPSTATUS LOOPSTATUS isdisplayed 2 When LOOP STATUS LOOP STATUS LOOP STATUS LOOP STATUS LOOP STATUS is displayed press any one of the top four select keys The display will read ARM ARM ARM ARM ARM BYPS BYPS BYPS BYPS BYPS ALR AL...

Страница 19: ...tically reset during system disarming When Bypass Loops is selected you will be asked to enter your code number When the code number is accepted you may enter the desired loop number and bypass or reset it A report of bypassed or reset loops can be transmitted to your central station This report is optional and is programmed during system installa tion Step By Step Step By Step Step By Step Step B...

Страница 20: ...OOP MONITOR is displayed press any one of the top four select keys The display will read ENTER CODE ENTER CODE ENTER CODE ENTER CODE ENTER CODE 3 Enter your code number and press The display will read PERIM ALL NBR PERIM ALL NBR PERIM ALL NBR PERIM ALL NBR PERIM ALL NBR PERIM 4 Press to place all disarmed perimeter loops into loop monitor PERIM is displayed on all perimeter systems only ALL Press ...

Страница 21: ...ER OKAY AC POWER OKAY AC POWER OKAY AC POWER OKAY AC POWER OKAY Monitors Status A C POWER A C power OKAY Normal BATTERY Battery power TRBL Trouble User Code Level User Code Level User Code Level User Code Level User Code Level None Function Function Function Function Function Displays the condition of internal system power and wiring System Status will display the condition of the internal system ...

Страница 22: ...ODE SYSTEM TEST 3 Enter your code number and press The system test begins automatically The display will read 1 BELL SOUNDING BELL SOUNDING BELL SOUNDING BELL SOUNDING BELL SOUNDING during two second bell test then 2 BATTERY OKAY BATTERY OKAY BATTERY OKAY BATTERY OKAY BATTERY OKAY or BATTERY TRBL BATTERY TRBL BATTERY TRBL BATTERY TRBL BATTERY TRBL to indicate condition of battery then 3 TRANSMIT T...

Страница 23: ... x x x x x x x Alarm Silence x x x x x x x System Test x x x x x x Loop Monitor x x x x x x Bypass loops Extend x x x x Schedules x x x Set Time x x Remote Authorization x x User Codes x only during permanent or temporary schedules Area Access The area numbers which may be armed or disarmed by a code number One or two areas may be available in your system Each User Code can have a different combin...

Страница 24: ...n and return to step 5 for the next User Code to be deleted If DELETE is pressed the display will show 6 If ADD or CHG is pressed the display will read USER NUMBER USER NUMBER USER NUMBER USER NUMBER USER NUMBER 6a Enter the user number to be added or changed and press The display will then read CODE NUMBER CODE NUMBER CODE NUMBER CODE NUMBER CODE NUMBER 6b Enter the one to five digit Code Number ...

Страница 25: ... 30 1 2 31 1 2 32 1 2 1 1 2 Ambush Code 2 1 2 3 1 2 4 1 2 5 1 2 6 1 2 7 1 2 8 1 2 9 1 2 10 1 2 11 1 2 12 1 2 13 1 2 14 1 2 15 1 2 16 1 2 User Code Area Number Number Access Person Assigned To User Code Area Number Number Access Person Assigned To Optional Not Functional on All Perimeter Systems ...

Страница 26: ...24 ...

Страница 27: ...ete Permanent and Temporary Schedules Schedules is used to enter permanent and temporary opening and closing times for your burglary system When Schedules is selected you will be asked to enter yourcodenumber Whenthecodenumberisacceptedyouwillbeaskedifyouwant to enter Permanent or Temporary Schedules Permanent Schedules and Temporary Schedules provide opening and closing times for your burglary sy...

Страница 28: ...L TIME M CL TIME M then DELETE DELETE DELETE DELETE DELETE KEEP KEEP 5c Press tokeepthecurrentscheduleandreturntostep5a DELETE Press to delete the current schedule The display will read OPENING TIME OPENING TIME OPENING TIME OPENING TIME OPENING TIME then AM PM AM PM AM PM AM PM AM PM An area number is requested only if your system is programmed to utilize a separate permanent or temporary schedul...

Страница 29: ...evel User Code Level User Code Level None for time display 8 to reset time Function Function Function Function Function Displays day time and date Timeisusedtodisplaythecurrentdayoftheweek thetimeofdayanddateofyear The day time or date can also be reset When time is selected the day of week and time of day are displayed followed by the date and year If no changes are to bemadedonothingandthedispla...

Страница 30: ...ODE 3 Enter your code number and press The display will read AUTHORIZED 1 HR AUTHORIZED 1 HR AUTHORIZED 1 HR AUTHORIZED 1 HR AUTHORIZED 1 HR User Code Level User Code Level User Code Level User Code Level User Code Level 8 Function Function Function Function Function Authorizes remote functions for one hour Remote Authorize is used to give your central station access to your alarm system for remot...

Страница 31: ... EVENTS User Code Level User Code Level User Code Level User Code Level User Code Level None Function Function Function Function Function Displays past system events The Display Events menu option will list past loop activity area arming and disarming and internal system status The events are automatically stored in the system memory for retrieval and display on the keypad The system may hold a ma...

Страница 32: ...30 LT 0149 3 93 ...

Отзывы: