174
z
System uses too much CPU resources. Please stop record first and then begin backup.
z
Data amount exceeds backup device capacity. It may result in burner error.
z
Backup device is not compatible.
z
Backup device is damaged.
17. Keyboard can not control device.
There are following possibilities:
z
Device serial port setup is not correct
z
Address is not correct
z
When there are several switchers, power supply is not enough.
z
Transmission distance is too far.
18. Alarm signal can not been disarmed.
There are following possibilities:
z
Alarm setup is not correct.
z
Alarm output has been open manually.
z
Input device error or connection is not correct.
z
Some program versions may have this problem. Please upgrade your system.
19. Alarm function is null.
There are following possibilities:
z
Alarm setup is not correct.
z
Alarm cable connection is not correct.
z
Alarm input signal is not correct.
z
There are two loops connect to one alarm device.
20. Remote control does not work.
There are following possibilities:
z
Remote control address is not correct.
z
Distance is too far or control angle is too small.
z
Remote control battery power is low.
z
Remote control is damaged or device front panel is damaged.
21. Record storage period is not enough.
There are following possibilities:
z
Camera quality is too low. Lens is dirty. Camera is installed against the light. Camera
aperture setup is not correct.
z
HDD capacity is not enough.
z
HDD is damaged.
22. Can not playback the downloaded file.
There are following possibilities:
z
There is no media player.
z
No DXB8.1 or higher graphic acceleration software.