11 

Installation |  

 

Installation

Installation

Installation

Installation    

The alarm should be mounted centrally within the premises and as far away as possible from windows and 
doors. It should be secured to a wall or located on a piece of furniture, close to a wall power socket. 

Using the 

Using the 

Using the 

Using the a

a

a

alarm

larm

larm

larm    

 

 
Press the green button on the radio key-fob 
(fig.  24)  for  one  second.  The  alarm  will 
emit a 1 beep signal. The red alarm active 
light  will  flash  for  30  seconds  and  then 
remain  illuminated  indicating  that  the   

alarm is now active. 

 
 
 
 
 

Press the red button on the radio key-fob for one second. The alarm will emit a 2 beep signal to 
confirm that it is not active and the red alarm active light will not be illuminated. If a 3 beep 

signal  occurs  this  indicates  that  the  alarm  siren  has  been  in  operation  during  your 
absence. Attention! 
 

 

 
Press the green and red buttons simultaneously for one second and the alarm siren will operate 
immediately.  To  stop  the  alarm  siren  press  the  red  button  for  one  second  and  the  alarm  will 
emit a 3 beep signal. This indicates that the alarm siren has been in operation. 
 
 

 

 
When the siren is in operation the red alarm active light will flash continually even when the 
alarm  stops  automatically  after  3  minutes.  This  light  will  stop  flashing  when  the  alarm  has 
been  de-activated  by  pressing  the  red  button  of  a  key-fob  and  the  alarm  will  emit  a  3  beep 
signal. This indicates that the alarm siren has been in operation. 

 

 

 
 
 
 

ON 
 
 

fig.24 

OFF 
 
 

PANIC 
 
 

Note 
 
 

Содержание AR6000

Страница 1: ...AR6000 alarm Purchase date Purchased from Security Alarms Co SA Printed in Switzerland 06 2010 ...

Страница 2: ...controlled intruder alarm radio controlled intruder alarm radio controlled intruder alarm Advanced security system for your home and office Advanced security system for your home and office Advanced security system for your home and office Advanced security system for your home and office Installation instructions e ...

Страница 3: ...des 4 Installation sequence 6 Alarm siren 10 Calibrating the infrasonic detector 10 Installation 11 Using the alarm 11 Battery life 12 Fault finding when the alarm is not activated 13 Fault finding when the alarm is activated 14 Set up accessory naming and fault finding via remote diagnostics 15 Interface port 16 Specification 17 Wall fixing template 18 Warranty 19 ...

Страница 4: ...plication Never use the alarm if it is damaged Do not install the unit near a heat source Do not allow children to use the alarm without supervision or previous operating experience Do not expose the cable from the transformer to a direct heat source and make sure that it is safely secured Never put the unit in water Clean with a damp cloth making sure that the power supply transformer is disconne...

Страница 5: ...re programmed electronic filtering system for analysis and when found positive activate the alarm siren immediately But the intruder is still on the outside of your home or office According to the Police when an intruder hears an alarm siren that he has set off 9 times out of 10 he will immediately leave the premises This modular security system can also be used with radio or wired door window con...

Страница 6: ... tamper and radio jamming protection The alarm has an automatic 24 hour anti tamper protection which is activated when it is lifted from its mounting When the alarm is activated all operating switches are protected If the alarm is lifted from its support or a switch is moved the alarm siren will operate immediately If the alarm radio receives any kind of radio jamming signals for more than 30 seco...

Страница 7: ...e protected 5 Diagnostic port RS232 link for programming interrogation and set up 6 Interface port A B C D E F system armed remote armed etc Jumpers Siren Delay Immediate Jumper fitted Pre alarm beep siren with 15 seconds delay Jumper not fitted Program Memory closed Jumper fitted Memory open to add new codes Jumper not fitted Tone Level Normal alarm disarm beeps Jumper fitted Quiet alarm disarm b...

Страница 8: ...ly 3 Key fob operation fig 7 ON press green button one beep OFF press red button two beeps PANIC press green red buttons at the same time The siren will operate for 3 minutes To STOP press red button three beeps 4 Radio code learning mode For key fobs and radio accessories Each key fob is randomly coded 59 000 codes by the factory There should be no need to re code them Make sure that each accesso...

Страница 9: ...e alarm is now in the code learning mode 4 5 Press key fob button green ON or red OFF on all key fobs 4 beeps will confirm that the each code has been learnt 4 6 Replace the Program jumper fig 13 If the alarm is to be used without accessories two short beeps will confirm that the codes have now all been recorded in the memory And then ignore instruction 4 7 4 11 4 7 Accessories only code learning ...

Страница 10: ...been learned no beeps will occur It will only beep for new codes 4 10 For standard accessories Set switch to zone 3 Zones 1 2 Do not re code accessories already coded in zone 1 2 fig 17 The green zone 1 2 lights will flash Then activate the relevant accessory and 3 beeps will confirm that the code is learned for activation in zone 1 2 combined Other accessory codes can also be learned and 3 beeps ...

Страница 11: ...of all learnt codes Set switch to Test fig 20 The green test light will be illuminated and you can now individually check the activation of the key fobs and all the accessories with their relevant security zones In the Test mode Key fobs produce 4 beeps Accessories produce 1 2 or 3 beeps and the relevant zone light will be illuminated briefly Accessories operating 24 hours day produce 5 beeps and ...

Страница 12: ...high will not increase protection but only make the likelihood of false triggering Make sure that all windows are closed and that all internal doors within the area to be protected are open Set the switch to Test fig 21 22 Remove the protection cover at the rear of the alarm Set the sensitivity button to the marked 50 position of the total sensitivity of the microphone by turning it to the left or...

Страница 13: ...beep signal to confirm that it is not active and the red alarm active light will not be illuminated If a 3 beep signal occurs this indicates that the alarm siren has been in operation during your absence Attention Press the green and red buttons simultaneously for one second and the alarm siren will operate immediately To stop the alarm siren press the red button for one second and the alarm will ...

Страница 14: ...mportant that the AR6000 is plugged into the electricity mains supply at all times The operational life of most accessory alkaline batteries is about 15 months under normal circumstances You are recommended however to change all alkaline accessory batteries at least once a year The operational life of the radio key fob lithium battery is about 5 years under normal circumstances You are recommended...

Страница 15: ...ns electrical supply has failed or the transformer is not connected Check that the mains terminal plug is correctly positioned When in doubt call your installer Observation The green Test light flashes Answer A radio accessory has a fault or its battery is low To locate the faulty accessory switch to test mode and activate each radio accessory in turn until you see the blue power light flash and a...

Страница 16: ...elf Answer The alarm cannot go off by itself It may be responding to inaudible signals Generally the sensitivity is set too high and should be lowered or recalibrated or there is other radio equipment in the vicinity that is illegally sending our radio interference signals When in doubt call your installer Observation The alarm is not triggered by opening a sliding door window Answer The infrasoni...

Страница 17: ...Pro which is available from this site http www brothersoft com tera term pro 10856 html Set the remote terminal program to the following settings Com Check in Device Manager to get the Com port number Bits per second 19 200 Data bits 8 Parity none Stops bits 1 Flow control none Command line interface Open up the correct terminal program Once you have the terminal window open enter help and you wil...

Страница 18: ...iredd w AlarmTamper Wiredd w AlarmSmoke BellboxTamper SwitchTamper Zone2 3 Zone2 d w_kitc Volumetric Volumetric Zone2 3 Zone2 d w_kitc Panic 1 KeyFob Peter KEY Alarm Denotes the alarm channel activated Number Order in which the RF accessory was learnt Type Denotes the Alarm Zone Name RF accessory programmed name Interface port Interface port Interface port Interface port Functions as follows A 0V ...

Страница 19: ...my up to 5 days of stand by capacity Operating temperatures 0ºC to 40ºC Back up battery 7 AA 1 5 volt lithium non rechargeable batteries Casing Moulded ABS resistant plastic with anti sabotage protection Dimensions 250mm x 190mm x 80mm Weight 800 gms Radio key fob 59 000 self learning codes Fitted with 3 volt Lithium Cell J CR2032 This equipment complies with the European R TTE directive see www s...

Страница 20: ... Wall fixing template 18 Wall fixing template Wall fixing template Wall fixing template Wall fixing template ...

Страница 21: ... or property damage or its inability to operate or any other incidental or consequential damages This warranty does not cover defects resulting from accidents damage whilst in transit to our service location alterations unauthorised repair and failure to follow operating instructions misuse fire flood and Acts of God This warranty does not cover the lithium batteries in the alarm in the radio key ...

Отзывы: