INSTALLATION STEP 6

Install the Light

The remote light (opener light) is designed to plug directly
into a standard 120V outlet.

1. Install the hinge and latch clips. Clips slide in between

the metal plate and the plastic housing on each side of
the light base (Figure 1).

2. Select an appropriate location on the ceiling to mount

the light within 6' (1.8 m) of an electrical outlet so that
the cord and light are away from moving parts.

3. Install the ceiling mount plate with the screws provided.

Leave 1/8" (3.1 mm) of the thread exposed between the
ceiling and the screw head (Figure 2).

NOTE:

If installing remote light (opener light) on drywall

and a ceiling joist can not be located, use wall anchors
provided. No pilot hole is required for wall anchors.

4. Determine the length of power cord needed to reach the

nearest outlet. Wind any excess cord around cord
retainer on the top side of the light base.

5. Install the light base by pushing onto the screws and

turning the base clockwise to lock the light in place.

6. Install two Type A19 incandescent or compact

fluorescent bulbs. 100 watt maximum per bulb,
200 watts total.

7. Install the light lens by hooking one end of the lens over

the hinge and pressing up on the other end to latch into
place (Figure 3).

8. Plug in the light to outlet.

NOTE:

Light will not operate until the unit is activated.

To prevent possible OVERHEATING of the endpanel or light
socket:
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
• DO NOT use bulbs larger than 100W.
• ONLY use A19 size bulbs.

W

all Anchors

Sce

w

s

Cord 
Retainer

Figure 2

Hinge Clip

Latch Clip

Metal 
Plate

Plastic
Ho

u

sing

Light 
Base

Light Clip
Scre

w

Light Clip Scre

w

Figure 1

Light
Lens

100 

W

att (max)

Figure 3

Scre

w

 #6x1" (2)

W

ll A

h

(2)

Light Clip Scre

w

#4-20 X 7/16" (2)

HARDWARE SHOWN ACTUAL SIZE

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of SEVERE INJURY or DEATH:

WARNING

WARNING

WARNING

WARNING

1. This portable luminaire has a polarized plug (one blade is

wider than the other) as a feature to reduce the risk of
electric shock.

2. This plug will fit in a polarized outlet ONLY one way. 
3. If the plug does not fit fully in the outlet, reverse the plug.
4. If it still does not fit, contact a qualified electrician.

5. NEVER use with an extension cord unless plug can be fully

inserted.

6. Do not alter the plug.
7. Light is intended for ceiling mount and indoor applications

ONLY.

Содержание Elite 3800P

Страница 1: ...re connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located behind the hinged door of your opener GARAGE DOOR OPENER Model 3...

Страница 2: ...t 6 Installation 7 16 Installation safety instructions 7 Position the opener 7 Attach the emergency release rope and handle 8 Install the power door lock 8 Attach the cable tension monitor Required 9...

Страница 3: ...below Must have minimum of 2 1 2 6 4 cm between the garage wall and the center of the torsion bar Must have minimum of 3 7 6 cm between the ceiling and the center of torsion bar Must have minimum of 8...

Страница 4: ...oor opener at 120V 60 Hz to avoid malfunction and damage To prevent possible SERIOUS INJURY or DEATH ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An u...

Страница 5: ...Connector Remote Light Opener Light with Hardware Bag Smart Control Panel LOCK L G I HT Carton Inventory Your garage door opener is packaged in one carton which contains the motor unit and the parts i...

Страница 6: ...t 12 14 ft lbs of torque Figure 2 NOTE For most installations the screws should be facing up for easy access Do not tighten set screws until indicated 6 Collar Screw Collar Screw Set Screw ASSEMBLY ST...

Страница 7: ...hnician if garage door binds sticks or is out of balance An unbalanced garage door might not reverse when required Operator MUST be mounted at a right angle to the torsion bar to avoid premature wear...

Страница 8: ...nector into the motor unit Figure 2 NOTE Lock must be mounted within 10 of the power head NOTICE Overhand Knot Emergency Release Handle Overhand Knot Rope Motor Unit Emergency Release Cable To prevent...

Страница 9: ...ble it on the opposite side of the cable tension monitor 1 Position the cable tension monitor as shown Figures 1 and 2 The cable tension monitor should be located as close to the drum as possible NOTE...

Страница 10: ...en snap cover in place 3 For standard installations ONLY Run bell wire up wall and across ceiling to motor unit Use insulated staples to secure wire in several places Do NOT pierce wire with a staple...

Страница 11: ...total 7 Install the light lens by hooking one end of the lens over the hinge and pressing up on the other end to latch into place Figure 3 8 Plug in the light to outlet NOTE Light will not operate un...

Страница 12: ...Install a 90o conduit or flex cable adapter to the 7 8 hole Reinstall opener to torsion bar Run wires through conduit cut to proper length and strip insulation Attach with wire nuts provided Properly...

Страница 13: ...unit Position the BBU as desired to a structural support ceiling joist or wall stud Attach the BBU to the support using the mounting holes on either side of the BBU Secure the BBU using the 1 1 2 lag...

Страница 14: ...other across the door no more than 6 15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting b...

Страница 15: ...with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 and 3 Place th...

Страница 16: ...wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If the green indicator light in the receiving eye is off dim or flic...

Страница 17: ...indicator light starts flashing slowly then release 2 Push and hold the black button until the door reaches the desired UP open position Figure 2 NOTE Check to be sure the door opens high enough for...

Страница 18: ...d to open and close your door The door must travel through a complete cycle UP and DOWN in order for the force to be set properly If the unit cannot open and close your door fully inspect your door to...

Страница 19: ...est The Protector System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button to close the door The door will not...

Страница 20: ...n on the emergency release handle until a click noise is heard from the unit and lift the door manually To reconnect the door to the opener pull down the emergency release handle straight down a secon...

Страница 21: ...ol Panel is activated Bulb size is A19 Bulb power is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door With a Smart Control Panel this f...

Страница 22: ...able the motion sensor when using the opener lights as working lights Otherwise they will turn off automatically if you are working beyond the sensors range Lock feature Designed to prevent operation...

Страница 23: ...n metallic surface This allows the sensor to recalibrate itself Dim LED lights Replace two 3V2016 batteries with same type 3V2016 coin cells No rapid LED blinking after pressing a button Replace two 3...

Страница 24: ...to match the remote control code Refer to instructions on the motor unit panel Repeat with all Remote 4 The remote control has short range Change the location of the remote control in your car Check t...

Страница 25: ...power door lock 12 The opener won t operate due to power failure Manually open the power door lock Use the emergency release handle to disconnect the door The door can be opened and closed manually W...

Страница 26: ...on the Smart Control Panel Pressing the Prog LEARN button again will allow the user to program an additional remote control to the opener Meaning This message will appear when the Prog learn button ha...

Страница 27: ...nit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending indicator light glows steadily receiving indicator light is dim...

Страница 28: ...s 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light...

Страница 29: ...d hold the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then press Enter The opener light will blink four times 3 To set the numb...

Страница 30: ...emote wall control or keyless entry 3 It has learned the code and the light turns on Reprogramming Light or Additional Light Your garage door opener remote light has already been programmed at the fac...

Страница 31: ...ell wire white white red 8 41A6104 Cable tension monitor 9 41C0902 Mounting bracket 10 41A5034 Safety sensor kit receiving and sending eyes with 3 9 m 2 conductor bell wire attached KEY PART NO NO DES...

Страница 32: ...DESCRIPTION 1 41DJ001 Logic board complete with plate 2 41A6408 Absolute Encoder System 3 41C168 Transformer KEY PART NO NO DESCRIPTION 4 41A6095 Motor with bracket 5 41B122 Power cord 6 41A6348 3 Co...

Страница 33: ...l sensor modules 915LM Garage Door Monitor Sensor Additional accessory sensor for homes with multiple garage doors 916LM EverCharge Battery Backup System Provides backup power to the model 3800 and 35...

Страница 34: ...34 OPERATOR NOTES...

Страница 35: ...35 OPERATOR NOTES...

Страница 36: ...s limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Seller...

Отзывы: