Secure SSR 302 Скачать руководство пользователя страница 9

9

 

 

Node Information Frame - NIF

 

Pressing and holding the two white buttons for 1 second 
will  trigger  the  SSR  302  to  issue  a  Node  Information 
Frame and enter Classic learn mode for 2s and then in 
NWI(Network Wide Inclusion) learn mode. This is useful 
when associating / disassociating the  SSR 302 with a 
control  group  or  just  to  determine  the  device  and 
command classes supported. This can be done at any 
time but will not provide any indication to the operator.

 

 

End Point Capability Reports

 

The  unit  supports  two  static  end  points  for  the  two 
channels.

 

Pressing the Top White button for 1 second will issue an 

‘end point capability report’ for Zone 1.

 

Pressing  the  Bottom  White  button  for  1  second  will 
issue an 

‘end point capability report’ for  Zone  2.

 

Broadcasting in this manner has been implemented to 
support  association  of  a  channel  with  a  3rd  party 
controller  that  supports  Multi-Channel  Command 
Class.

 

Note: This product can be included and operated in any 
Z-Wave  network  with  other  Z-Wave  certified  devices 
from other manufacturers and/or other applications. All 
non-battery operated nodes within the network will act 
as repeaters regardless of vendor to increase reliability 
of the network.

 

Содержание SSR 302

Страница 1: ...SSR 302 User and Installation Instructions Two channel 3 Amp switch Rx Z Wave...

Страница 2: ...nds This SSR 302 will act as a repeater once added into the Z Wave network providing an alternative communication route for units which otherwise would not be within communication distance of each oth...

Страница 3: ...function Both White buttons Network function Solid Amber Unit is added on to a network and a Zone has not timed out to failsafe mode to indicate loss of communication Top White button held for Zone 1...

Страница 4: ...White buttons Network function Flashing Amber One of the Zones has entered failsafe mode With Top White button held or Bottom White button held the Red and Green buttons switches relay output off and...

Страница 5: ...The backplate should be fitted with the wiring terminals at the top and in a position which allows a total clearance of at least 50mm around the receiver Direct Wall Mounting The receiver should ideal...

Страница 6: ...ng can only enter from beneath the receiver and must be securely clamped The mains supply terminals are intended to be connected tothesupply bymeans of fixed wiring The receiver is mains powered and r...

Страница 7: ...tions Fitting the Receiver If surface wiring has been used remove the knockout insert from the bottom thermostat to accommodateit Fit the receiver to the backplate ensure the lugs on the backplate eng...

Страница 8: ...tsflashinggreen The SSR 302 has been added onto the network and theLEDwill gosolidamber NOTE If the LED does not flash green the add process has beenunsuccessful Removing from a Network To remove from...

Страница 9: ...nit supports two static end points for the two channels Pressing the TopWhite button for 1 second will issue an end pointcapabilityreport forZone1 Pressing the Bottom White button for 1 second will is...

Страница 10: ...006 SSR 302 Device ID Type 0 and 1 for serial number Data format Binary length 4 Bytes Version V2 Get Report Version Command Class Get Version Command Class Report Provides the version number of the Z...

Страница 11: ...des having endpoints Product supports one group Lifeline and has a maximum of 4 nodes Association Group Info V1 Group Name Get Group Name Report Group Info get Group Info Report Group Command List Get...

Страница 12: ...command class as follows Basic Set Mapped to Switch Binary Set Basic Get Mapped to Switch Binary Get Basic Report Mapped to Switch Binary Report Same as Switch Binary command class there is no failsa...

Страница 13: ...vice comes in factory default state and will not send device reset locally notification This command is used to independently access the two channels available on the SSR 302 Product has 2 identical n...

Страница 14: ...t Software class Class A Receiver category Category 3 Power class Class B Mechanical Dimensions 120mm x 90mm x 32mm Case material thermoplastic flame retardant Ball pressure test Temperature 75 C Moun...

Страница 15: ...together com European Sales Office CEWE Instrument AB Box 1006 611 31 Nyk ping t 46 8 600 80 60 e info securetogether com www securetogether com www securetogether com Australia Sales Office Secure Au...

Страница 16: ...4 2492 300 05 f 91 294 2492 310 e mktg securetogether com www securetogether com Elegant Metering Solutions FZE 4EA 326 P O Box 54857 Dubai Airport Free Zone Dubai UAE p 971 50 6575166 f 971 04 204 56...

Отзывы: