Secure SRT323 Скачать руководство пользователя страница 5

The  aerial  symbol  complete  with  radio 
wave  symbols  in  the  display  of  the 
SRT323  thermostat  indicates  that  it  is 
wirelessly communicating with the rest of 
the system.

If the SRT323 is connected to a wider wireless system, 
a  flashing  radio  wave  would  indicate  a  loss  of 
communication. This may be temporary and can often 
be  restored  by  turning  the  thermostat  dial  and 
increasing or decreasing the temperature to make the 
thermostat send a temperature update to a controller.     
If this has no effect please see Wireless System Setup 
instructions on page 9.

5

Содержание SRT323

Страница 1: ...SRT323 User and Installation Instructions 1 Electronic Room Thermostat Temperature Sensor Tx Z Wave...

Страница 2: ...the demand temperature and to report back the relay state The SRT323 will only operate when 2 x AAA batteries have been fitted This document provides information specific to the Z wave technology impl...

Страница 3: ...ing your comfort levels In fact comfort levels may well be improved as the control accuracy should ensure that the room does not overheat before switching off The display will show the required temper...

Страница 4: ...it is assumed that the thermostat has been incorporated into a Z Wave system When the thermostat is in the call for heat condition a flame symbol will appear in the display Pressing the temperature se...

Страница 5: ...T323 is connected to a wider wireless system a flashing radio wave would indicate a loss of communication This may be temporary and can often be restored by turning the thermostat dial and increasing...

Страница 6: ...are nearing the end of their life a low battery symbol will appear in the display and the batteries should be changed within a few days If the batteries are not changed at this point eventually a LO...

Страница 7: ...nal markingsin the battery compartments 7 Once the batteries are fitted re fit the thermostat to the wall plate by engaging with the lugs at the top of the wall plate and push the thermostat into posi...

Страница 8: ...raditional thermostat When used with a condensing boiler the TPI thermostat will help to save energy as the control algorithm allows the boiler to operate in condensing mode more consistently compared...

Страница 9: ...o ON position on the back of the unit scroll through the function menu by rotating the dial To select the required function press the dial On selecting a function the character will start flashing whi...

Страница 10: ...Information Frame NIF Learn Mode use this command for 1 3 Include to or exclude from a controller see page 11 Receive Period Enabled Listening This function will keep the unit awake for 60sec to rece...

Страница 11: ...ill reporta failure 3 All association settings will be lost if learn mode has been activated with another controller regardless of a pass or fail result any association settings will have to be re con...

Страница 12: ...ith the radio signals The SRT323 should be mounted on an internal wall approximately 1 5 metres from floor level using the wall plate provided and should be in a position away from draughts direct hea...

Страница 13: ...accordance with the wiring diagrams and fit the terminal covers Mounting the Thermostat Onto the Wall Plate Complete the installation by swinging the room thermostat into position by engaging with the...

Страница 14: ...conductors Earth continuity must be maintained and all bare earth conductors must be sleeved Ensure that no conductors are left protruding outside the central space enclosed by the wall plate The S h...

Страница 15: ...ion for boiler with built in timer and external room stat This diagram is schematic and should be used for guidance only 15 COMBINATION BOILER TERMINALS E N L REMOVE LINK IF FITTED MAINS SUPPLY E N L...

Страница 16: ...tic and should be used for guidance only 16 COMBINATION BOILER TERMINALS E N L REMOVE LINK IF FITTED MAINS SUPPLY E N L 1 2 3 4 For precise terminal connection information please refer to boiler manuf...

Страница 17: ...Port Mid Position Valve with a Secure SHP021 SHP027 electronic programmer This diagram is schematic and should be used for guidance only 17 1 2 3 4 5 6 L N MAINS SUPPLY E N L 1 4 1 4 FROST STAT IF FIT...

Страница 18: ...pring Return Valves with auxiliary switches and a Secure SHP021 SHP027 electronicprogrammer This diagram is schematic and should be used for guidance only 18 1 2 3 4 5 6 L N MAINS SUPPLY E N 4 FROST S...

Страница 19: ...ET command with a Multilevel Sensor REPORT This report can be requested or sent unsolicited to the nodes in Group 5 If the temperature sensor functionality is disabled the SRT323 will report 0x8000 Ba...

Страница 20: ...mode is type Heat Command Class Thermostat Setpoint The Setpoint type of Heating is supported Command Class The SRT323 will accept Setpoint SET commands only if the Setpoint type is Heating SRT323 wil...

Страница 21: ...a maximum of 4 nodes Configuration The unit supports 3 single byte configuration Command Class parameters for the temperature sensor in the range 1 3 respectively Configuration Parameter Number 1 Defa...

Страница 22: ...n and or Wake up 15 Mins Electrical Purpose of Control Contact Rating ContactType Supply ControlAction OperatingTime Limitation Software Class Radio Compliance RF Frequency Receiver Category Power Cla...

Страница 23: ...mental Impulse Voltage Rating Enclosure Protection Pollution Degree Operating Temperature Range Compliance Design Standards 86mm x 86mm x 36 25mm Thermoplastic flame retardant 75 C Wallplate Cat II 25...

Страница 24: ...877 Issue 1 24 CEWE Instrument AB Box 1006 611 31 Nyk ping t 46 8 600 80 60 e info securetogether eu www securetogether eu European Head Office Secure Controls UK Ltd Roman Farm Road Bristol BS4 1UP...