background image

 

 

 

Advance Mode 

Function Description 

Add device

(1)

 

Include any Z-Wave device into its network  

Remove device

(1)

 

Exclude any Z-Wave device from network  

Activate Learn mode

(1)

 

Start Learn process for inclusion / Exclusion from other network 

Enter listening mode

(1)

 

Listen mode for sending Wakeup Notification to wake up node if configured 

Broadcast device 
Information 

Broadcast its Node Information Frame (NIF) 

Check  
signal  
strength

 (2)

 

RF signal strength test using power level CC with associated node in Group 2  

Outcome 

Network Health 

Action on associated node 

3 bars 

Good 

No action 

2 bars 

Acceptable 

May move node, or install repeater node in-between 

1 bar 

Insufficient 

Must move node, or install repeater node in-between 

 

Factory reset 

Perform protocol reset, set thermostat configurations to factory default.  
Note: 

Please use this procedure only when the network primary 

controller is missing or otherwise inoperable.

 

Associate Channel

(1)

 

Associate node in group 2 by Classic / Multichannel association, using NIF / 
Multichannel capability report from other Z-Wave device (node). 

Remove channel 
association

(2)

 

Remove associated node from association group 2 

View associated 
channel ID

(2)

 

Display associated end point (Channel number ) in association group 2 

Display Text 

Description 

None 

No End point available in  association group 

CH x 

End point x ( 1 to 127 ) available in  association group 

 

Change fuel type

(2)

 

Used to Set / Change boiler fuel type to configure TPI cycle. 

View fuel type

(2)

 

View present boiler fuel type.  

Lock/unlock 
temperature set point 

Disable / Enable set-point change using Up/Down buttons. 

Role transfer

(1)

 

Shift primary role to the new controller in network  

Exit

(3)

 

Exit from advance mode 

1. 

Maximum time out for activity is 55 seconds. 

2. 

Operation applicable if node available in association group 2. 

 

SUPPORTED DEVICE AND COMMAND CLASSES 

Z-Wave Device Classes 

Implemented Device Class 

Generic  

Multilevel Sensor 

Specific 

Routing_Sensor_Multilevel 

Basic  

Portable Controller 

Command Classes 
Supported

 

Description

 

Manufacturer Specific 

(V2)

 

Secure Controls (UK) Manufacturer ID, Device serial number 

Version 

(V2)

 

Provides the version number of the firmware, hardware and supported 
Command Classes.

 

Device Locally reset 

(v1)

 

Used to inform lifeline node that the device has been factory reset, and is 
leaving the network. 

Z-Wave Plus Info 

(v2)

 

Z-Wave Plus Version 1 

Role Type - ROLE_TYPE_CONTROLLER_PORTABLE_REPORTING 

Отзывы: