ProLogic L22
Operation Instructions
5
1.5 Testing the Lock Operation
The ProLogic L22 comes with two factory default codes:
•
Super Code (ID00) is 111111
•
Manager Code (ID01) is 123456
Enter one of the valid codes to verify that the communication between the lock and EntryPad. The lock
will open.
2.0 Code Length Options
IMPORTANT: This must be completed before any programming.
The ProLogic L22 allows you the ability to select the code length for all safe lock operators and the total
number of users allowable on the lock. Setting the code length and number of Users is a global setting
and applies to all safe lock operators.
Note: If you skip this step and program the lock, you can change the Code Length/Number of Users at a
later time.
All safe doors must be opened to make this change as a reset will be required on all lock
bodies.
All programming will be deleted and the lock will be set back to default.
There are 3 options available as follows:
Code Length 6 digits – 10 total codes available - This is the default mode and meets the UL
requirement.
Code Length 8 digits – 30 total codes available – This mode also meets the UL requirement.
Code Length 6 digits – 30 total codes available – This mode does not meet the UL requirement.
2.1 PW L – 6; Users – 10 – This is the default mode
NOTE: This operation must be performed with the SAFE DOOR OPEN and with access to the back of
the lock, as a mechanical reset must be performed during this programming sequence
.
Step1: Press the Menu/OK button.
Step 2: Using the
and
, scroll to the System Menu and Press Menu/OK.
Step 3: The display will prompt you to enter a valid code. Enter the Super Code (ID00) only .
This function is not available to Manager Codes ID01 or ID02. The “Select Menu” message will
be displayed as follows:
Step 4: Scroll
and
to the menu selection “PW L – 6; Users – 10” and Press OK