in the following figure. Hold down the left mouse button and draw the setting area (the default all areas
are selected as the monitoring region).
Note: Region settings are only available in the motion detection function of analog channel in hybrid
mode / full analog mode.
“Period”:The recorder will trigger the motion detection alarm signal within the set time range. It can be
set by week, or it can be set uniformly, and four time periods can be set every day. Check the check
box before the time period ■, the set time will take effect.
“Interval” During the set interval time, the motion detection alarm is triggered multiple times to output
only one alarm signal;
“Record Delay”After setting the motion detection alarm, the recorder will continue to detect the time
period of the recording, and the setting range is 10~300 seconds.
“Recording channel”: Set the channel number of the linked recording when the motion detection alarm
is triggered (can be checked); when the alarm occurs, the recorder will record the selected channel;
Note: To use this function, you need to change the recording mode to configuration and set the
effective time period and start the detection recording in [Main Menu] > [Recording Function] >
[Recording Settings].
“Tour”: Set the channel number of the full-screen display when the motion detection alarm is triggered
(can be checked); when the alarm occurs, the recorder will cycle the full-screen display of the selected
channel;
Note: The interval between the full screen display of the selected channel during the tour process is