background image

Public holiday / vacation calendar

Menu: 

Permanent holidays: display / delete

- All entries can be viewed here and, if applicable, be deleted.

- To do this, select the one-time holiday to be deleted by means 

of the 

t

/

u

keys and then delete by pressing the ON key.

17

No. 02 
OFF :   DM      25:12
ON:     DM      27:12

<

Содержание SELO-BR

Страница 1: ...Electronic lock SELO BR Operating instructions for the additional functions Weekly timer holiday vacation calendar opening delay administrator functions Made in Germany www secu gmbh de ...

Страница 2: ...holidays 12 Creating one time holidays 13 Displaying or deleting one time public holidays 14 Permanent holidays 15 Creating permanent holidays 16 Displaying or deleting permanent holidays 17 Opening delay 18 Calibrating clock 19 Change over summer time winter time 20 User functions 21 Create user Edit user 22 Administrator functions 23 Code modification by user is authorised 25 Reset timer functio...

Страница 3: ...lock is switched on it will automatically start up in the standard mode again Change over Standard system Æ Backup system Press On Enter key Next press Function key Using the t ukeys keys 1 and 2 go to Menu Mode select Select by pressing the On Enter key Using the t ukeys go to Select Backup mode Confirm by pressing the On Enter key Next continue tipping on the Function key until you return to the...

Страница 4: ...ction key Using the t u keys keys 1 and 2 select Administrator menu Press On Enter key Using the t ukeys select Lite Mode menu Press On Enter key Enter your valid administrator code Key in the 4 digit Changeover code 7293 Press On Enter key To change the operating mode to Lite Mode confirm the setting once more by pressing the On Enter key Important All extended settings such as user calendar time...

Страница 5: ... in your valid user code Key in the 4 digit Changeover code 3195 and press On Enter key To change the operating mode to Professional Mode confirm the setting once more by pressing the On Enter key Note The new 7 digit Administrator code is the same as the previous user code from the Lite Mode All extended settings have to be re entered To change the number of digits of the code see comments on pag...

Страница 6: ...ukeys Time entry Î Enter and confirm hour Enter and confirm minute Date entry Î Enter and confirm day Enter and confirm month Enter and confirm year Access times Î page 8 6 Menu Timer functions 03 05 04 09 35 time entry 03 05 04 09 35 date entry 03 05 04 09 35 access times ...

Страница 7: ...ns of the t ukeys Holiday calendar Î page 11 Opening Delay Î page 18 Calibrating Î page 19 the timer Summer time Î page 20 7 03 05 04 09 35 Holidays calendar Menu Timer functions 03 05 04 09 35 Opening Delay 03 05 04 09 35 Calibrating timer Summertime MESZ MEWZ ...

Страница 8: ...Weekly timer Menu Access times Select sub menu by means of the t ukeys Timer A Î page 9 Timer B Î page 9 8 03 05 04 09 35 Access times Selection Timer A Selection Timer B ...

Страница 9: ...plies to all users with the exception of the administrator who has permanent access Note as long as no time window has been defined the lock is released for allocated users without limitation By means of the t u keys the individual time windows can be created or edited When editing the time windows individual days e g MO TU SU can be selected or the following time periods Mo Fr Sa So Mo Su OFF mea...

Страница 10: ...3 Fr 14 16 59 hours If time windows are programmed overlapping the command which was processed last of all will determine the status of the lock This allows for very flexible programming Example Time window 1 Mo Fr 8 16 hours Time window 2 Fr 14 30 15 hours The lock is open Mo Th from 8 16 hours On Friday it is only open from 8 15 hours because the lock switches to closed at 15 hours If for one pa...

Страница 11: ...n calendar Menu Holiday calendar Select sub menu by means of the t ukeys One time Î page 12 holidays Permanent Î page 15 holidays 11 03 05 04 09 35 Holiday calendar 03 05 04 09 35 One time holidays 03 05 04 09 35 Perm holidays ...

Страница 12: ...y vacation calendar Menu One time holidays Select sub menu by means of the t ukeys Holiday create Î page 13 Holiday display delete Î page 14 12 03 05 04 09 35 One time holidays Holiday create Holiday display delete ...

Страница 13: ...lidays One time holidays are variable e g Easter or a summer vacation After they have expired they are deleted automatically A public holiday can cover a single day such as Late summer holiday e g Late summer holiday OFF DMY 30 08 04 on the 30th August 04 ON DMY 31 08 04 A public holiday can also cover a period of several days e g Easter OFF DMY 09 04 04 9th to 13th April 04 ON DMY 14 04 04 e g su...

Страница 14: ...holidays display delete All entries can be viewed here and if applicable be deleted To do this select the one time holiday to be deleted by means of the t u keys and then delete by pressing the ON key 14 No 02 OFF DMY 09 08 04 ON DMY 28 08 04 ...

Страница 15: ...vacation calendar Menu Permanent holidays Select sub menu by means of the t ukeys Holiday create Î page 16 Holiday display delete Î page 17 15 03 05 04 09 35 Perm holidays Holiday create Holiday display delete ...

Страница 16: ...permanent public holidays Permanent holidays are fixed on a particular date e g New Year or Christmas They are copied to the subsequent years and do not need to be re programmed year after year When programming permanent holidays the year is not entered A public holiday can cover a single day e g New Year OFF DM 01 01 on the 1st January ON DM 02 01 A public holiday can also cover a period of sever...

Страница 17: ...rmanent holidays display delete All entries can be viewed here and if applicable be deleted To do this select the one time holiday to be deleted by means of the t u keys and then delete by pressing the ON key 17 No 02 OFF DM 25 12 ON DM 27 12 ...

Страница 18: ... administrator After the first code has been entered the programmed delay is counted down afterwards the code must be entered once again the authorised person has 5 min time for this this period cannot be modified If 5 minutes pass without the code being entered again the entire procedure must be repeated Delays between 00 s and 99 s can be programmed A delay of 00 means that the opening delay is ...

Страница 19: ...precision you can calibrate it Example measured deviation 1 min 60 sec in 90 days this results in a correction factor of 60 sec 90 days 0 7 seconds per day Input select the sign by means of the t u keys and then enter the calculated correction value 19 correction factor 00 7 sec Tag ...

Страница 20: ...er time Menu Summer time The timers can automatically change over to summer time or to winter time This function can be activated by means of the t u keys CEST function is activated OFF function is deactivated 20 Summer time CEST ...

Страница 21: ...Select sub menu by means of the t ukeys Create Î page 22 Modify Î page 22 Display Î Select and confirm user Delete Î Select and confirm user Delete data with ON key 21 User Create Menu User User Modify User Display User Delete ...

Страница 22: ...owed together with two further persons ADMI access and programming authorisation in the 2nd line on the right the user can be allocated to a weekly timer page 9 A timer A B timer B not allocated to a timer in the 3rd line the user is allocated a code ______________________________________________________ Example C Koenig has access authorisation alone 1 is allocated to weekly timer B and has the a...

Страница 23: ...usly programmed codes After the code has been changed from 8 to 7 digits use only the first 7 digits of any previously programmed code When the code is changed back from 7 to 8 digits at a later date the original 8 digit codes will become valid once more Restructure Î Restructuring of database Function reserved for servicing Edit user code Î page 25 23 Menu Administrator Administrator Code length ...

Страница 24: ...Select sub menu by means of the t ukeys Reset timer functions Î page 26 Ident number Î Here the ident number of the lock can be requested 24 Administrator Reset timer func Menu Administrator Ident number XXXX YYYY ZZZZ Administrator Ident number ...

Страница 25: ...on Here the administrator defines whether the users may edit their access code themselves Select by means of the t u keys Yes The users may edit their access code themselves No Only the administrator may edit the access code of the users 25 Code modification Yes ...

Страница 26: ...asily delete all the entries in the weekly timer the public holiday calendar or the opening delay WARNING All entries will be irrevocably deleted Please note After the reset all users who are allocated to a timer and therefore only have limited access will gain an unlimited access right 26 Delete entries with ON key ...

Страница 27: ...s Menu Process Select sub menu by means of the t ukeys Reset timer functions Î Enter administrator code Select process The last 1000 processes can be displayed 27 Administrator 01 06 06 07 42 Code changed Menu Process ...

Страница 28: ...Display lock information Menu Info The openings counter allows you to check the total number of times the lock has been opened 28 SECU SELO BR 1 0 Count 00001744 ...

Страница 29: ...kte GmbH Wormgermuehle D 58540 Meinerzhagen Germany www secu gmbh de mail secu gmbh de Irrtum und Änderungen vorbehalten Omissions and changes reserved Sous réserve de fautes d erreurs et de modifications BA SELO BR VF 01 2006 ...

Отзывы: