In order to call for a help (the premises must be secured by CMS) press at once two specific keys and hold
them at least 1 second. When emergency alarm occurs, siren starts to sound and alarm message will be
shown on the keypad display.
Fire alarm
–
.
Medical alarm –
.
Panic alarm
–
.
ž
ž
ž
+
+
+
A
1
B
4
C
7
Disarming by PIN code, when entering the premise
After opening the door, which are protected, the system begins to count the entry delay. During this time it is
necessary to enter PIN code and confirm by pressing the
key. All partitions, which are controlled by
User, will be disarmed.
ENT
Disarming by PIN code, when staying in protected premise
When all partitions are armed and the entry door weren’t opened, after entering PIN, all partitions, which
are controlled by User, will be disarmed. Disarming:
.
When part of partitions are armed and the entry door weren’t opened, after entering PIN it is necessary to
make decision either to arm disarmed partitions or to disarm armed ones.
Full disarming :
, [Disarming]
, [All partitions]
.
Partial disarming:
, [Disarming]
, [Selected parti]
, [Parts:]
.
PIN:
ENT
PIN:
ENT
ENT
ENT
PIN:
ENT
ENT
ENT
ENT
Disarming when staying in protected premise – BB or F0
Nevertheless, are there all partitions armed or not, all partitions, which are controlled by User, will be
disarmed. Disarming :
F-key:
or
ž
.
F
0
ENT PIN:
ENT
B
B
ENT PIN:
ENT
The first partition disarming, when staying in premise - B1
Nevertheless, are there all partitions armed or not, the first partition, which is controlled by User, will be
disarmed. Disarming:
F-key:
.
The second partition can be disarmed with
ž
.
, both partitions with
B
1
ENT PIN:
ENT
B
2222
B
1
2222
Event log review – F30, F31
All events, which are concerned with protected premises and status of the system, are stored in the event
log. Reviewing event log:
F-key:
(ALARMS events),
(FAULTS events).
Via Menu:
[Event Log]
, [Alarm Event]
, [PIN:]
.
To display time or date event press the
key
the
,
.key
ž
ž
, next event is selected
F
3
0
ENT
F
3
1
ENT
ENT
ENT
ENT
PIN:
ENT
If an alarm has occured, on the display appears message “Alarm
There are 2 ways to clear alarm and turn off red LED:
way – pressing the
After performed alarm clearing action siren stops to sound
– entering PIN code.
After performed alarm clearing action siren stops to sound, alarm LED goes off, the system will be disarmed
if it was armed before entering PIN code. When all partitions, which are controlled by User, are disarmed, it's
not recommended to use PIN for alarm clearing, because is possible casual arming.
!!!” with an explanation, what reason
caused it. Alarm LED is turned on, the siren starts to sound and report about alarm is sending to CMS or to
the User.
2 way
ž
ž
1
.
, alarm LED goes off, the system status remains
the same as was before alarm. If the system has smoke detector and alarm was caused by smoke, which
was raised by domestic reasons, the system will start alarm, nevertheless it was armed or disarmed. The
only way to clear alarm is possible by bypassing of smoke detector (see
“Bypassing zone – B”).
2 page,
CLR PIN:
ENT
Alarm clearing
Electronic notebook (memo) review - F09
All important contact information
1 record
2 record
3 record
4 record
5 record
1 record]
2 record]
3 record
4 record
5 record
(phone No, e-mail) Installer can write out on keypad. Review:
F-key:
, [
]
, [
]
, [
]
, [
]
, [
]
.
Via Menu:
[memo
, [
, [
, [
]
, [
]
, [
]
.
ž
ž
F
0
9
ENT
ENT
ENT
pre-alarm
trouble
armed
alarm
Ways of disarming
Disarming can be done by three ways: F-key, entering PIN code, Via Main Menu. Using F-key or entering PIN, all
partitions, which are controlled by User, will be disarmed. After disarming via Menu it’s necessary to unmark the partition,
which we don't want to protect. The partition, which will be disarmed, is denoted the
or
keys and this action is confirmed
by pressing the
key.
ENT
Short user manual
Intruder alarm system