ENFORCER Twin Photobeam Detectors
SECO-LARM U.S.A., Inc.
7
The sensor beam frequency can be set at different levels on-site to avoid interference from other
twin photobeam sensors nearby, which is useful during multiple sensor applications as shown
below. To select between four different beam frequencies, adjust the beam channel switch of the
transmitter side and receiver side. See fig. 1 for switch location and table 2 for switch position.
Important -
The transmitter and receiver sensor pair must be set with the same frequency.
Multiple Sensor Sample Application (For E-964-D390Q model only):
Selectable 4 – Channel Beam Frequency (For E-964-D390Q Model Only):
Frequency
channel CH1 CH2 CH3 CH4
Switch
position
Table 2: Beam Frequency Selection Chart (For E-964-D390Q model only)
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1.
Single pair multiple layer application.
Tx
Ch1
Rx
Ch1
Sensor #1
Tx
Ch2
Rx
Ch2
Sensor #2
Sensor #3
Tx
Ch3
Rx
Ch3
Tx
Ch4
Rx
Ch4
Sensor #4
Tx
Ch1
Rx
Ch1
Rx
Ch2
Tx
Ch2
Tx
Ch3
Rx
Ch3
Rx
Ch4
Tx
Ch4
2.
Long distance series application.
Sensor #1
Sensor #2
Sensor #3
Sensor #4