SECO-LARM No-Cut Door Strike 

 

2

 

                                                        

SECO-LARM U.S.A., Inc.

 

1x  Door Strike 

2x  Electrical connectors 

2x  Wiring connectors 

2x  Mounting tabs 

2x  Wood screws 

4x  Machine screws 

2x  Machine screws (narrow) 

2x  Security screws 

2x  Anchor nuts 

1x  Manual 

   

   

 

 
 

 

Model 

SD-993C-D3Q 

Operating voltage 

12/24 VDC 

Current draw 

12VDC 

300mA  

24VDC 

150mA  

Latch throw 

9

/

16

" (15mm) 

Keeper width 

1

7

/

16

" (36mm) 

Static strength 

1,500 lbs. (680kg) 

Dynamic strength 

70 ft-lbs. (9.68 m-kgs) 

Endurance 

100,000 cycles (UL Tested), 1,000,000 cycles (Factory Tested) 

Operating temperature 

32°~120° F (0°~49° C) 

Operating humidity 

0

~

85% 

Dimensions 

4

7

/

8

"x1

1

/

4

"x1

1

/

16

"  (124x32x27.5 mm) 

 

Specifications: 

Note: 

Not all parts will be used in every installation.

 

Parts List: 

Dimensions: 

1.

 

Using a flathead screwdriver, unscrew and remove 

the screw cap to access the field-selectable plug. 

2.

 

For fail-safe operation, rotate the field-selectable plug 

so that "1" is facing up. 

3.

 

For fail-secure operation, rotate the field-selectable 

plug so that "2" is facing up.  

4.

 

Replace the field-selectable plug in the correct 

orientation and screw the screw cap back into place. 

Selecting Fail-Safe or Fail-Secure: 

1

7

/

16

"  

(36mm) 

1

1

/

4

" (32mm) 

4

7

/

8

"  

(124mm) 

1

1

/

16

" (27.5mm) 

3

1

/

8

"  

(79mm) 

3

3

/

8

"  

(85mm) 

4

1

/

8

"  

(105mm) 

Field-selectable Plug 

Screw Cap 