ENFORCER 12VDC 6-in-1 Battery Tester with Continuity
4
SECO-LARM U.S.A., Inc.
Battery load test fails
Charge the battery fully for best results.
Replace battery being tested.
Voltage drop test fails
Use SECO-LARM ST-HB105-TTQ Voltage Booster to increase the
amount of voltage present.
Reduce length of wiring.
Decrease gauge of wire used (increase thickness of wire).
PTC fuse test fails
Check PTC soldering to make sure it is correctly applied.
Replace PTC fuse.
Continuity test yields false negative
Change the internal battery. Be sure to store tester in Voltage Test mode.
Troubleshooting:
WARRANTY
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The
sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole
or in part, without the written permission of SECO-LARM.
SECO-LARM
U.S.A., Inc
.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
E-mail: [email protected]
PITSW1
mi-ST-BT02Q_1009.docx
Order Part #763-168%
Test #6: PTC Fuse Test (12VDC Only)
1.
Use the tester to determine whether a PTC fuse can be used with a given device load.
2.
Always wait about 30 seconds for the tester and fuse to cool before and after performing tests.
3.
Using the alligator test leads, connect the clips to the leads or terminals of the fuse being tested.
4.
Tester load selection: 0.5A when device load to be used is 0~0.5 A; 1.0A when device load is 0.5~1.0 A.
5.
Press and hold LOAD button for about 3 seconds. Read fuse condition according to the image below.
Blue: Excellent
Green: Good
Yellow: Weak
Red: Bad
If the fuse tests “Weak” or “Bad:
Test another fuse. If the test yields the same results,
the load may be too great. Try a lower load.
If test still yields “Weak” or “Bad,” replace the fuse.
Changing the Battery (Use type 3VDC CR1220 battery):
1.
Open the top of the case by applying pressure inward and upward at the point right above the
mounting hook on one side. The top cover will unclip. The PC board may come out, this is normal.
2.
Use a fingernail to gently push the gold-colored metal retaining strip on the battery holder away
from the battery. The battery will pop free. Replace only with a
3VDC CR1220
type dry cell battery.
3.
After replacing the battery, snap the cover back on one side at a time. Ensure internal wires are
not pinched by housing or housing guide pins and that indicator LEDs are correctly aligned.