background image

ENFORCER Curtain Sensors

 

8

 

SECO-LARM U.S.A., Inc. 

The receiver and the transmitter both have a tamper switch on one end to protect against someone 
attempting to open the unit. However, there is no separate tamper output to the alarm control 
panel. Instead, the alarm output is triggered if the cover of the end cap with the tamper button is 
removed, if the transmitter or receiver is moved out of alignment, or if power is disconnected.  

 

NOTICE: 

The information and specifications printed in this manual are current at the time of publication. However, the 

SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to 

change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Trademarks 
are the property of SECO-LARM U.S.A., Inc. or their respective owners. 

Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or 
in part, without the written permission of SECO-LARM. 

 

LIMITED WARRANTY:

 

This SECO-LARM product is warranted against defects in material and workmanship  while 

used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to 

the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty 
is  void  if  damage  is  caused  by  or  attributed  to  acts  of  God,  physical  or  electrical  misuse  or  abuse,  neglect,  repair  or 

alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such 
equipment  is  not  operating  properly  as  a  result  of  causes  other  than  defects  in  material  and  workmanship.  The  sole 

obligation  of  SECO

-

LARM  and  the  purchaser’s  exclusive  remedy,  shall  be  limited  to  the  replacement  or  repair  only,  at 

SECO-LARM’s  option.  In  no  event  shall  SECO-LARM  be  liable  for  any  special,  collateral,  incidental,  or  consequential 

personal or property damage of any kind to the purchaser or anyone else. 

 

SECO-LARM

®

 

U.S.A., Inc

.

 

16842 Millikan Avenue, Irvine, CA 92606 

Website: www.seco-larm.com 

 

PICTN1

 

Phone: (949) 261-2999  |  (800) 662-0800  Email: [email protected] 

MiE-96xx-xxB25_141008.docx 

 

Tamper Protection:

 

Troubleshooting:

 

Transmitter LED will not turn 
ON 

 

Test the power and ground wire with a voltage meter to 
ensure power is connected and is of the correct voltage. 

 

Change the position of the transmitter jumper “JMP0” 
(see page 6). 

Receiver LED will not turn ON 

 

Test the power and ground wire with a voltage meter to 
ensure power is connected and is of the correct voltage. 

Receiver LED will not turn ON 
unless the sensor is triggered  

 

Change the position of the receiver jumper “JMP1”  
(see page 6). 

Receiver LED flashes 
continuously 

 

Check that the transmitter and receiver are aligned. 

Does not trigger when beam is 
broken 

 

Remount the curtain sensor away from any shiny surface, 
or repaint the surface to cut down on reflection. 

Receiver continuously triggers 
the alarm 

 

Check that the transmitter and receiver are aligned. 

 

Check that the tamper button and the cover for the 
tamper button are mounted correctly. 

False alarm 

 

Re-install so that multiple sensors do not interfere with 
each other. 

 

Cut back leafy vegetation. 

 

Re-mount away from the edge of a roof. 

 

Mount under a roof or shelter. 

 

 

Содержание Enforcer series

Страница 1: ...Model Number of Beams Length Color E 9680 10B25 10 80 Black E 9660 8B25 8 60 Black E 9644 6B25 6 44 Black E 9644 6W25 6 44 White E 9622 4B25 4 22 Black E 9622 4W25 4 22 White E 9611 2B25 2 11 Black E...

Страница 2: ...5 16 x7 8 33x22 mm Rugged aluminum construction NO NC Relay output 2 4 6 8 or 10 separate photoelectric beam sensors programmable trigger upon breaking of any single beam or simultaneous breaking of a...

Страница 3: ...es or other leafy vegetation see Fig 1 Do not mount where water running off the roof might break the beam see Fig 1 The sensor and beams must be sheltered Do not mount near reflective surfaces as this...

Страница 4: ...ew frequency is selected 2 Both the transmitter and the receiver of each pair must be set to matching frequencies to work together correctly 1 Find a suitable location see Fig 1 a The transmitter and...

Страница 5: ...he end caps see Fig 5 and pull the tamper buttons out of the end caps one per transmitter or receiver and locate the mounting holes Using these holes as a template mark their location on the wall with...

Страница 6: ...e Reinsert the cap over the tamper button and small tamper cap Note 1 Screw the wires tightly to avoid slipping off the terminals but not so tight that they break 2 Unused terminal screws should be ti...

Страница 7: ...adjacent beams or any single beam depending on programming 4 The curtain sensor also has red LEDs which can be used for testing purposes see Table 2 5 After the curtain sensor is tested and aligned pe...

Страница 8: ...n or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM an...

Отзывы: