background image

ENFORCER Voice Dialer 

8

 

SECO-LARM U.S.A., Inc. 

 

 

Note: 

1.

 

When the dialer is in standby mode and the (

) icon is ON, the auto dial is disabled.  

2.

 

When the dialer is in standby mode and the (

) icon is OFF, the auto dial is enabled. 

 

Setting the Auto Dial Function  

The user can choose whether or not the dialer will dial the emergency numbers when triggered. 
The factory default is “ON”. 

1.

 

Enter the PIN number and press the [PROG] button five times or until the phone icon (

flashes on the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept.  

3.

 

Press the [#/DOWN] or [*/UP] button to select either “ON” or “OFF” and press the 
[ARM/DISARM] button to accept. The dialer will “beep” once. 

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Programming the Voice Dialer, continued: 

Setting the Number of Auto Dial Cycles 

This can be set from 1~5 cycles. The factory default is 3 cycles, meaning that the voice dialer will 
dial each programmed number 3 times.  

1.

 

Enter the PIN number and press the [PROG] button six times or until “CYCLE” flashes on the 
LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

Press the [#/DOWN] or [*/UP] button to select your choice of 1-5 cycles and press the 
[ARM/DISARM] button to accept. The dialer will “beep” once. 

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Setting the Number of Call-in Rings 

This sets the number of call-in rings after which the voice dialer will answer. The factory default is 
5 rings, but can be user programmed for 3, 5, 7, or 10 rings. 

1.

 

Enter the PIN number and press the [PROG] button seven times or until the bell icon ( ) 
flashes on the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

Press the [#/DOWN] or [*/UP] button to select 3, 5, 7, or 10 and press the [ARM/DISARM] 
button to accept. The dialer will “beep” once.  

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

 

ENFORCER Voice Dialer  

SECO-LARM U.S.A., Inc. 

9

 

 

Programming the Voice Dialer, continued: 

Setting the Entry Delay Time 

This allows the user to set the length of time before the alarm will sound, to allow time to disable 
the alarm after normal entry. The factory default is 20 seconds, but can be user programmed for 0, 
5, 10, 15, or 20 seconds. 

1.

 

Enter the PIN number and press the [PROG] button eight times or until “ENTRY” flashes on 
the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

Press the [#/DOWN] or [*/UP] button to select 0, 5, 10, 15, or 20 seconds and press the 
[ARM/DISARM] button to accept. The dialer will “beep” once. 

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Setting the Date and Time 

1.

 

Enter the PIN number and press the [PROG] button nine times or until the clock icon (

flashes on the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

The date and time will appear on the LCD screen as 5 sets of numbers representing the year, 
month, date, hour, and minute respectively. The first set of numbers (year) will be flashing, 
indicating that this can now be changed.  

4.

 

Press the [#/DOWN] or [*/UP] button to select the correct number for the year and press the 
[ARM/DISARM] button to accept and move to the next position. Repeat for each position until 
complete. 

5.

 

Press the [PROG] button until the programming icons disappear to exit the setup mode. 

Note: 

Time is shown using a 24 hour clock. 

 

Record and Play Back Emergency Message 

1.

 

Enter the PIN number and press the [REC/PLAY] button. Speak your message into the 
microphone of the voice dialer. The maximum message length is 20 seconds. When finished, 
press [REC/PLAY] again.  

Note: 

You may wish to include instructions for disarming the unit in your message since you 

may not remember how to do so at a later date when you receive a message that the alarm 
has been triggered.  

A suggested message could be, “{Your name}’s security alarm has been activated. Please 
enter a command, 1# to monitor the room, 2# to broadcast a message to the room, 3# to end 
this call, or 6# to disarm the system.” 

2.

 

To listen to a message, press the [REC/PLAY] button. 

Содержание Enforcer E-921CPQ

Страница 1: ...ed to monitoring and recording audio and video signals SECO LARM will not be held responsible for the use of this product in violation of any current laws or statutes NOTE While the system can provide valuable protection to home and property when properly installed it cannot guarantee complete protection against intrusion SECO LARM is not responsible for any losses or damage which may occur during...

Страница 2: ...Planner 14 FCC Part 68 14 Summary Programming Operation Chart 15 Also Available from SECO LARM 15 Troubleshooting 16 ENFORCER Voice Dialer SECO LARM U S A Inc 15 Summary Programming Operation Chart 1 Setting Changing PIN Number see pg 6 Current PIN PROG ARM DISARM New PIN ARM DISARM PROG x9 2 Setting Emergency Telephone Numbers see pgs 6 7 PIN PROG x2 ARM DISARM DOWN or UP Enter Phone ARM DISARM P...

Страница 3: ...ould affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with this equipment US 7M7TE02BE921CPQ for repair or warranty information please contact SmartRG Inc If the equipment is causing harm to the telephone network the telephone company m...

Страница 4: ... chime will sound and the word HOME will appear on the LCD screen 2 After 60 seconds another chime indicates that the voice dialer is now in the Home mode 3 When a sensor is activated the voice dialer will chime twice 4 If the panic button is pressed the voice dialer will sound a 30 second alarm and start the dialing sequence to the programmed emergency numbers To deactivate the Home mode simply p...

Страница 5: ...m system 5 Disarm system 6 The user should hear a beep in response If not enter the function code again ENFORCER Voice Dialer SECO LARM U S A Inc 5 Installing the Voice Dialer continued 1 Select a location for the dialer near a standard electrical outlet if user supplied 12VDC adapter is to be used a telephone wall jack and the alarm control panel but out of sight The dialer should not be exposed ...

Страница 6: ... and holding for two seconds the DOWN or UP buttons respectively The sign shows as and the sign shows as on the LCD screen ENFORCER Voice Dialer SECO LARM U S A Inc 11 2 To disarm the system enter the PIN number and press the ARM DISARM button The dialer will sound a long beep and the word ARM will disappear from the LCD screen Panic Button Use 1 When the PANIC button is pressed the siren will sou...

Страница 7: ...nnected only to the TEL jack of the dialer ENFORCER Voice Dialer SECO LARM U S A Inc 7 Deleting a Stored Phone Number 1 Enter the PIN number and press the PROG button twice or until MEMORY flashes on the LCD screen 2 Press the ARM DISARM button to accept 3 Press the DOWN or UP button to select the number you wish to delete 4 Press the DEL PAUSE button to delete the number 5 Press the DOWN or UP bu...

Страница 8: ...programming icons disappear to exit the setup mode ENFORCER Voice Dialer SECO LARM U S A Inc 9 Programming the Voice Dialer continued Setting the Entry Delay Time This allows the user to set the length of time before the alarm will sound to allow time to disable the alarm after normal entry The factory default is 20 seconds but can be user programmed for 0 5 10 15 or 20 seconds 1 Enter the PIN num...