7
①
Put the
Punch sticker
on a suitable position on the wall, use a percussion drill to make an outlet
hole with a diameter greater than 14mm and four plastic screw holes with a diameter of 6mm,
and then insert four matching plastic screws;
②
Use a screwdriver Unscrew the anti-dropping
screw just below the side of the product, remove the bottom case of the product, and fix the
bottom case on the wall with four matching self-tapping screws on the wall according to the hole
position of the bottom case.
③
According to the selected wiring diagram, cut the lead wires to a
suitable length, and cut off the excess wires, and connect them to the system wires one by one
according to the wiring diagram through the wall or in the embedded box. Be careful not to
connect wrongly or Short circuit, otherwise the machine may be burnt out. After checking all is
correct, shortly power on to test whether the indicator light is normal and the buzzer beeps,
otherwise immediately cut off the power supply, recheck whether the wiring is correct, and after
it is correct, install the front shell of the product on the bottom shell on the wall. Remove the
screws and fix it.
④
Attach the decorative sheet to the position of the anti-dropping screw.
The product wiring colors and functions are shown in the following table
:
Color
Symbol
Functions
Red
+12V
Positive pole
Black
GND
Ground
Green D0
Wiegand signal, D0 input or output(or RS232-TTL signal output:
Tx)
White
D1
Wiegand signal, D1 input or output(or RS232-TTL signal input : Rx)
Brown D_IN
(
LED
)
Door contact input (or external control input of green
LED)
Yellow OPEN
(
BZ
)
Exit button input(or external control input of buzzer)
Blue
NO
Normal open port of Relay
Purple COM
Common port of Relay
Orange NC
Normal close port of Relay
Grey
Alarm-
Alarm (or doorbell) signal MOS drain output