4.1.17 Set Anti-crack function
43, 0#, default value, normal working mode.
43,1#, alarm working mode, when error operation times more than allowed times, the
machine alarm will beeps and it send out alarm signal.
43, 2#, locked working mode, when error operation times more than allowed times, the
machine will lock up for some time. User cannot press any key or read card during that time.
44, (1-10)#, default value is 10, set maximum times for the error operation from 1 to 10 .
45, (1-99)#, default value is 10, after the error operation exceeds the set maximum number
of times, it will be locked for 1-99 minutes.
Note: Anti-crack function refers to prevent illegal and unlimited password or card crack to
open the door in a short period of time, the basic method is within 10 minutes of invalid
password or invalid card number read error exceeds the default setting, the controller will alarm
or lock up for some time.
4.1.18 Set LED indicator light mode
50, 0#, standby, LED indicator light is off.
50, 1#, default value, standby, LED indicator light always red.
50, 2#, standby, LED turns green in reader mode, LED turns red in other modes.
4.1.19 Adjust the brightness of the normally bright red indicator
51, 1, 1, ... ,decrease brightness
51, 2, 2, ..., increase brightness
Note: The brightness of the indicator light can be adjusted total 21 different levels. Each
time you press the “1” key, it decrease 1 level of brightness. Press and hold on the “1” key, the
brightness will continuously decrease. When it reaches to minimum level of brightness, the
controller will beep twice. Each time you press the “2” key, it increase the level of brightness.
Press and hold on the “2” key, the brightness will continuously increase. When it reaches to the
maximum brightness the controller will beep twice.
4.1.20 Set buzzer mode
54, 0#, disable buzzer.
54, 1#, default value, enable buzzer.