13
10. Reset to Factory Default
Power off, press the RESET key (SW14) on the PCB, hold it and power on,
release it until hear two short beeps, the LED shines in orange, then read
any two EM cards, the LED will turn in red, means reset to factory default
setting successfully. Of the two EM cards read, the first one is Manager
Add Card, the second one is Manager Delete Card.
Remarks: Reset to factory default setting, the users' information enrolled
is still retained. When reset to Factory setting, the two Manager cards must
be re-enrolled.
11. Sound and Light Indication
LED
Buzzer
Shines
Red
Slow
Shines
Red
Slow
Shines
Red
Slow
Long Ring
3
Rings
Short
2
Rings
Short
Orange
Green Shines
Operation Status
Reset to factory default setting
Sleeping mode
Stand by
Enter into programming mode
Exit from programming mode
Wrong operation
Open the door
Alarm
Alarm
Red Shine
Shines
Red
Fast
Long Ring
Long Ring
Finger Sensor
Shine
Figure
4
-
-
+
+
Lock 1
-
+
-
+
DC12V/3A
+
-
Power
Door 2
Alarm 2
Alarm 1
Lock 2
Exit Button 1
Door 1
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
D0
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
F007EM-II Controller 1
F007EM-II Controller 2
Exit Button 2
Door Detecting
Switch 1
Door Detecting
Switch 2