Sebury F007EM-II Скачать руководство пользователя страница 13

11

If

 

the

 

controller

 

is

 

PC

 

connection

the

 

users

 

ID

 

can

 

be

 

shown

 

in

 

the

 

software

.

a

Card

 

user

its

 

ID

 

is

 

the

 

same

 

as

 

the

 

card

 

number; 

b

Fingerprint

 

user

its

 

ID

 

is

 

the

 

combination

 

of

 

device

 

ID

 

and

 

fingerprint

 

ID

 

The

 

device

 

ID

 

is

 

set

 

as

 

below

*   Master Code   #   3   device

 

ID   #   

 

Note

Device

 

ID

 

can

 

be

 

any

 

digit

 

of

 

0

-

255

For

 

example

device

 

ID

 

was

 

set

 

255

fingerprint

 

ID

 

is

 

3

then

 

its

 

ID

 

to

 

the

 

controller

 

is

 

255

 

00003

.

F007EM
Wiegand

 

26

 

interface

 

can

 

connect

 

to

 

it

 

as

 

its

 

slave

 

reader

no

 

matter

 

it

 

is

 

ID

 

card

 

or

 

IC

 

card

The

 

connection

 

is

 

showed

 

as

 

Figure

 

2

When

 

add

 

cards

it

 

is

 

required

 

to

 

do

 

it

 

at

 

the

 

slave

 

reader

but

 

not

 

controller

 (

except

 

EM

 

card

 

reader

which

 

can

 

be

 

added

 

on

 

either

 

reader

 

or

 

controller

)

-II supports

 

Wiegand

 

input

any

 

card

 

reader

 

which

 

supports

 

9.  

2 F007EM-II

 

works

 

as

 

Controller

connecting

 

slave

 

reader

One

 

F007EM-II

 

installed

 

inside

 

the

 

door

the

 

other

 

outside

 

the

 

door

two

 

devices

 

interconnect

Either

 

device

 

acts

 

as

 

the

 

controller

 

and

 

reader

 

at

 

the

 

same

 

time

It

 

has

 

below

 

feature

Wiegand

 

output

Wiegand

 

input

The

 

connection

 

is

 

showed

 

as

 

Figure

 

3

9.3 Two

 

F007EM-II Interconnected-Single

 

Door

D0

D1

+12V

GND

-

+

Lock

-

+

EM card

HID card

IC card

DC12V/3A

+

-

Power

D0

D1

ALARM-

OPEN

D_IN

+12V

GND

VSS

L-

Green

White

Grey

Yellow

Brown

Red

Black

Blue

Purple

Orange

L+  

ALARM+

Wiegand reader 

Reader Plug

F007EM-II Controller 

Alarm 

Exit Button

Figure

 

2

Door Detecting Switch

Содержание F007EM-II

Страница 1: ...User Manual Fingerprint RFID Access Control...

Страница 2: ...7 9 Setting Two devices interlocked 7 10 Setting Alarm signal output time 7 7 Setting Door open detection 8 User Operation 8 1 User to Release the Door 8 2 Remove Alarm 9 Advanced Application 9 1 F00...

Страница 3: ...ure Infrared remote control master cards for programming 3000 users includes 1000 fingerprint users and 2000 card users Card interface EM 125KHz card Wiegand 26 input output Standalone or Wiegand read...

Страница 4: ...d the cable through the cable hole Attach the device to the back cover Remove the back cover from the device using the supplied security 4 Installation 2 Remote Control Sensor Fig 1 Schematics Wiring...

Страница 5: ...gand Output D0 Grey Alarm Negative 12V DC Positive Regulated Power Input Negative Regulated Power Input Brown OPEN 12V GND GND L L Alarm Function D1 D0 Alarm D IN Door Contact 6 Connection Diagram 6 1...

Страница 6: ...Green Brown Exit Button Red Black Alarm Door Contact Electric Bolt Special Power Supply L L F007EM Red Black Orange Purple EM Lock GND NO NC Special Power Supply Electric Control Lock GND NO NC Red B...

Страница 7: ...d 1 User card 2 User card Manager add card st nd Remarks Fingerprint user ID is 3 1000 Card user ID is 1001 3000 when add fingerprint or card by Manager Card it is produced automatically from 3 1000 o...

Страница 8: ...if it is lost th st nd To add card continuously 1 1001 1 card 1002 2 card N N card Or 1 1001 1 card number 1002 2 card number N N card number st nd th st nd th b ID number Appointment To add fingerpri...

Страница 9: ...ngerprint To Add User To add users continuously st nd th 2 user ID Remarks When delete users the Master can just delete its ID number and don t have to input fingerprint or card It is the good option...

Страница 10: ...255 This operation might be required when F007EM II is acting as Wiegand reader and connecting to multi door controller 7 6 Setting Lock style and door relay time Fail secure unlock when power on Mast...

Страница 11: ...de Setting Two devices interlocked 7 10 Setting Alarm signal output time Setting Alarm signal output time 9 0 3 Master Code Alarm time is 0 3 minutes for option factory default is 1 minute 7 7 Setting...

Страница 12: ...y of the method above can remove the alarm 8 2 Remove Alarm Remove Alarm 10 9 Advanced Application F007EM supports Wiegand output it can be connected to the controller which support Wiegand 26 input a...

Страница 13: ...at the slave reader but not controller except EM card reader which can be added on either reader or controller II supports Wiegand input any card reader which supports 9 2 F007EM II works as Controll...

Страница 14: ...mainly using in bank prison and other places where require higher security Two doors are installed for one access The user enters fingerprint or card on controller 1 the door 1 will open the user ent...

Страница 15: ...tion LED Buzzer Shines Red Slow Shines Red Slow Shines Red Slow Long Ring 3 Rings Short 2 Rings Short Orange Green Shines Operation Status Reset to factory default setting Sleeping mode Stand by Enter...

Страница 16: ...e Operating Humidity Resolution Fingerprint Input Time Identification Time FAR FRR Dimensions N W User Capacity Card Type Card Reading Distance G W DC 12V 10 20mA 80mA 10 50 20 RH 95 RH 450 DPI 1S 1S...

Отзывы: