4.  The first wireless smoke alarm detector automatically returns to the 

transmit mode

 after 

successful networking (LED is solid red). 

5.  To connect additional wireless smoke alarm detectors to the first wireless smoke alarm 

detector, press the TEST button on these wireless smoke alarm detectors until the LED lights 
turn red. Then release the TEST button immediately. The LEDs of the two wireless smoke 
alarm detectors flash for approx. 2s after successful networking. 

6.  After a short pause, the wireless smoke alarm detectors, which were previously switched in 

the

 learning

 

mode,

 start to beep for about a minute. This is a test alarm. Please do not mute 

the test alarm! This prevents the wireless connection from being checked for it´s function. 

7.  If there is no feedback from another wireless smoke alarm detector device within 30 seconds, 

the light from the LED stops flashing and the wireless smoke alarm detector, which is in the 

transmit mode

, will go into standby mode with a short beep. 

8.  As a last step you must make sure that all wireless smoke alarm detectors are connected 

together! Check networking only after 30 seconds at the end of the last test alarm and last 

transmit mode

. Press the TEST button for 30 seconds if the wireless smoke alarm is 

connected. While pressing the TEST button, the LED will turn red and the alarm will sound. 
After approx. 30s, all networked wireless smoke alarm detectors, which are within radio range, 
also begin to beep. This is a test alarm, which turns itself off after about a minute. If you want 
to terminate the test alarm prematurely, briefly press the TEST button of each wireless smoke 
alarm detector. 

 

RESET Mode

 

To assign a new random code, you must switch the wireless smoke alarm detector into the RESET 
mode. Press the TEST button for approx. 16 seconds until the LED flashes quickly. (While 
pressing the TEST button, the LED will flash red and the alarm sounds.) After the LED begins 
flashing fast, release the TEST-button immediately. Press the TEST button (the LED will light up 
red) twice in the sequence. After a short beep has elapsed, the activation of the RESET mode has 
been successful. 

Note:

  Always switch the wireless smoke alarm detector from standby mode to RESET mode! 

 

5.  Installation 

 

1.  Disconnect the mounting base by turning it counterclockwise from the case. 
2.  Hold the mounting base to this position on the ceiling, where you want to mount the wireless 

smoke alarm detector. Draw with a pencil the holes for the bores to the ceiling. 

3.  Then drill two holes (Ø 5mm). 
4.  Now take the two in the scope of delivery supplied dowels and put them in the bores. 
5.  Screw the mounting base to the ceiling. The screws are included in scope of delivery. 
6.  Then hold the wireless smoke alarm detector on the mounting base so that the two guide pins 

engage in the openings next to the retaining clips on the bayonet connection (

see in the 

mounting diagram

). 

7.  Through a short rotation of the housing clockwise and overcoming a slight resistance, the 

smoke detector can be securely fixed to the ceiling 

Содержание GS558

Страница 1: ...tup 5 3 1 Activation the wireless smoke alarm detector 6 3 2 Function control 6 3 3 Temporary muting the alarm 7 3 4 Recurrent self test of the wireless smoke alarm detector on its function 7 4 Networking of smoke alarms among each other 7 5 Installation 8 6 Replacing batteries 9 7 Notes to the use of batteries 10 8 Technical Data 10 9 Reasons for triggering a false alarm 11 10 Behavior in case of...

Страница 2: ...detector identifies the smoke and not the flame of a fire The smoke alarm detector is also reacting from a heat of 54 to 70 C This wireless smoke alarm detector type GS558 may only be used in private rooms After a maximum of 10 years as well this device must be replaced The wireless smoke alarm detector can detect a fire early by recognizing the smoke or the burning articles This device is not sui...

Страница 3: ...age it The conversion of this product is not allowed Another use than described may damage the product This product is only suited for indoor use and not for outdoor use Protect it against humidity and moisture splashing or dripping Damaged wireless smoke alarm detectors must be replaced immediately 2 Mounting location in rooms of the wireless smoke alarm detectors 2 1 Wireless smoke alarm detecto...

Страница 4: ...g of the room and spread horizontally The wireless smoke alarm detector should be placed possible so that this is at least 50cm from the side wall and 61cm mounted away from the corner of the room see Figure 3 Figure 3 Mounting the wireless smoke alarm detector on the ceiling On ceiling beams which are thicker than 20 cm no installation of wireless smoke alarm detector should be done A minimum dis...

Страница 5: ...ry dusty rooms With A shaped roofs the wireless smoke alarm detectors may not be mounted at the highest point Rooms having a room temperature of below 5 C or above 45 C In caravan or similar rooms In these living areas the attachment to the inside of parts are advised The air in the upper part of these areas as well as the ceiling is strongly warmed up by intense solar irradiation This can result ...

Страница 6: ...ss smoke alarm detector 3 2 Function control The TEST button is used to check the function of the wireless smoke alarm detector After pressing the key a very loud alarm will sound Keep the wireless smoke alarm detector at least an arm s length away from your body while pressing the TEST button Afterwards the alarm sounds briefly 3 times and the LED flashes In this case the function of the electron...

Страница 7: ...here are a total of over 60 000 encodings If a wireless smoke alarm detector is connected to another one it will accept the code of the other An already networked wireless smoke alarm detector which is to be connected to a new wireless smoke alarm detector takes over the code of the new device Please note that wireless smoke alarm detector may only be interlinked within an apartment or a family ho...

Страница 8: ...re within radio range also begin to beep This is a test alarm which turns itself off after about a minute If you want to terminate the test alarm prematurely briefly press the TEST button of each wireless smoke alarm detector RESET Mode To assign a new random code you must switch the wireless smoke alarm detector into the RESET mode Press the TEST button for approx 16 seconds until the LED flashes...

Страница 9: ...30 second intervals for 30 days With this it points out that the battery must be changed Additionally the LED flashes The wireless smoke alarm detector is still fully functional at this time However it is recommended to replace the battery as soon as the wireless smoke alarm detector is warning about the empty state of the battery Please always replace the battery with an identical battery type wh...

Страница 10: ...s are not to be re charged New batteries should not be used together with used batteries Please always use batteries with the same type Please always pay attention to the correct polarity when inserting the battery The connection terminals never short circuit Throw batteries never into the fire Keep batteries away from children and animals Please make sure that the batteries are not swallowed espe...

Страница 11: ...ure is the creation of an escape plan and the subsequent discussion with your roommates or your family If the fire cannot be extinguished with a fire extinguisher or a fire blanket by yourself then leave the house immediately Do not waste time to put clothes on or by transportation of personal objects because every second counts After leaving the house please inform the fire department immediately...

Страница 12: ...turn batteries and or accumulators gratuitous in the sales point or in their direct vicinity for example at municipal collection points and trade Otherwise you can also return the batteries and or accumulators by post to us SEBSON Gernotstr 17 44319 Dortmund Germany Batteries and or accumulators which contain harmful substances are marked with the symbol of a crossed out waste bin and may not be d...

Страница 13: ...pared according to the listed below guidelines Essential characteristics Perfomance Harmonised technical specification Nominal activation conditions Sensitivity Response delay response time and Performance under fire conditions PASS EN 14604 2005 AC 2008 Operational reliability PASS Tolerance to supply voltage PASS Durability of operational reliability and response delay temperature resistance PAS...

Страница 14: ...ity of operational reliability electrical stability PASS The declaration of performance for this product can be found under the following link www sebson de DOP_GS558_EN_N pdf SEBSON Sebastian Sonntag Gernotstr 17 44319 Dortmund Germany www sebson de ...

Отзывы: