4. The first wireless smoke alarm detector automatically returns to the
transmit mode
after
successful networking (LED is solid red).
5. To connect additional wireless smoke alarm detectors to the first wireless smoke alarm
detector, press the TEST button on these wireless smoke alarm detectors until the LED lights
turn red. Then release the TEST button immediately. The LEDs of the two wireless smoke
alarm detectors flash for approx. 2s after successful networking.
6. After a short pause, the wireless smoke alarm detectors, which were previously switched in
the
learning
mode,
start to beep for about a minute. This is a test alarm. Please do not mute
the test alarm! This prevents the wireless connection from being checked for it´s function.
7. If there is no feedback from another wireless smoke alarm detector device within 30 seconds,
the light from the LED stops flashing and the wireless smoke alarm detector, which is in the
transmit mode
, will go into standby mode with a short beep.
8. As a last step you must make sure that all wireless smoke alarm detectors are connected
together! Check networking only after 30 seconds at the end of the last test alarm and last
transmit mode
. Press the TEST button for 30 seconds if the wireless smoke alarm is
connected. While pressing the TEST button, the LED will turn red and the alarm will sound.
After approx. 30s, all networked wireless smoke alarm detectors, which are within radio range,
also begin to beep. This is a test alarm, which turns itself off after about a minute. If you want
to terminate the test alarm prematurely, briefly press the TEST button of each wireless smoke
alarm detector.
RESET Mode
To assign a new random code, you must switch the wireless smoke alarm detector into the RESET
mode. Press the TEST button for approx. 16 seconds until the LED flashes quickly. (While
pressing the TEST button, the LED will flash red and the alarm sounds.) After the LED begins
flashing fast, release the TEST-button immediately. Press the TEST button (the LED will light up
red) twice in the sequence. After a short beep has elapsed, the activation of the RESET mode has
been successful.
Note:
Always switch the wireless smoke alarm detector from standby mode to RESET mode!
5. Installation
1. Disconnect the mounting base by turning it counterclockwise from the case.
2. Hold the mounting base to this position on the ceiling, where you want to mount the wireless
smoke alarm detector. Draw with a pencil the holes for the bores to the ceiling.
3. Then drill two holes (Ø 5mm).
4. Now take the two in the scope of delivery supplied dowels and put them in the bores.
5. Screw the mounting base to the ceiling. The screws are included in scope of delivery.
6. Then hold the wireless smoke alarm detector on the mounting base so that the two guide pins
engage in the openings next to the retaining clips on the bayonet connection (
see in the
mounting diagram
).
7. Through a short rotation of the housing clockwise and overcoming a slight resistance, the
smoke detector can be securely fixed to the ceiling