background image

9

OPERATING INSTRUCTIONS

Starting The Machine

 

Your AIRBELT K canister is equipped with a soft start system and variable suction 
controls. To help you better understand the various power control options on your 
SEBO canister, please follow the instructions below. 

 

K3 Premium Users - Figures 1, 2, 3 & 4

 

Before turning on your canister, make sure that the vacuum handle is in its upright locked position. 

 
1. With the canister main power knob (9) in the OFF position, and the suction-control slider on the  

handle (#2a, figure 4) in the OFF position, pull the power cord out from the base of the canister  
(figure 1). The power cord should be unwound from the cable reel at least two thirds of its length.  

Note:

 do not over-extend the cord.   

2. Plug the polarized power cord into a 120 volt wall outlet located near the floor. 
3. Press the main power knob (9) on the base of the canister gently with your foot or hand. The green  

light (10) will illuminate indicating that the power is on.. 

4. Slide the suction-control slider (#2a, figure 4) toward the MAX position. It will move freely between 

0 suction and MAX suction. Set the slider to the suction desired.  

5.  When the power head is on with the handle in the upright locked position, the brush roller will not  

spin. To release the ET-1 power head from the upright locked position, press down on the foot  
pedal, (#41, figure 3), lower the handle into the normal operating position and push the brush  
roller switch on the handle (#2b, figure 4) to engage the brush roller. The green light on the power  
head will illuminate. The handle can be lowered to a horizontal position useful for vacuuming  
under beds. 

 

Note: K3 users - see the ET-1 Owner’s Manual for power head instructions.

 

 

K2 Turbo and K2 Kombi Users - Figures 1 & 2

 

Before turning on your canister, make sure that the vacuum handle is in its upright locked position. 

 
1. With the canister main power knob (9) in the OFF position, pull the power cord out from the base  

of the canister (figure 1). The power cord should be unwound from the cable reel at least two- 
thirds of its length. 

Note:

 do not over-extend the cord.   

2. Plug the polarized power cord into a 120 volt wall outlet located near the floor. 
3. Press the main power knob (9) on the base of the canister gently with your foot or hand.  

 
 
 

 

Suction Control  

K3 Premium Users - Figure 4

 

You may adjust the suction with the suction-control slider (2a) as you vacuum different 
surfaces or when using the accessory tools. For optimal cleaning and brushing, operate 
the machine at the maximum suction power setting and push the power head slowly over 
the carpet. 

 
When the canister’s main power knob (9) is in the ON position, you may turn the suction 
and the power head off and on with the suction-control slider (2a). To turn the power off 
using the suction-control slider, pull the slider to 0 suction, then continue pulling the slid-
er up until it “clicks” into the OFF position. The green power head light will then shut off 
(the green light on the canister (#10, figure 2) will remain illuminated until the vacuum is 
powered off using the main power knob).  
 
 
 

K2 Turbo and K2 Kombi Users - Figure 5

 

The on/off and suction-control knob is located on the top side of the canister (9). Rotate 
the knob counter-clockwise for maximum suction. Rotate clockwise to reduce suction 
for vacuuming curtains or delicate fabrics. 

Figure 1

22

6

Figure 2 

9

10

0

max.

Figure 4 - K3

2a

2b

Figure 3 - K3

41

0 = Zero Suction 

MAX = Maximum Suction  

ON position - Move the slider 

toward MAX.  

OFF position - Pull the slider up 

to 0 suction then continue 

pulling the slider up until it 

“clicks” into the OFF position.

Figure 5 - K2

9

Содержание AIRBELT K

Страница 1: ...OWNER S MANUAL For Household Use Only...

Страница 2: ...the Exhaust Filter 12 Changing the Pre motor Microfilter 12 Changing the AIRBELT Textile 12 Clog Removal 13 Clogs in the Head or Brush 13 Clogs in the Telescopic Tube 13 Clogs in the Hose 13 Clogs in...

Страница 3: ...st or vapors 20 Maintenance and repairs must be done by authorized personnel 21 Use only original SEBO replacement parts 22 Do not use vacuum as a step 23 If vacuum is used on plush carpet or carpet w...

Страница 4: ...e textile covering protects furniture walls and the vacuum itself from damage during use Personalized Vacuums AIRBELT canister vacuums can be personalized with a replacement AIRBELT textile available...

Страница 5: ...is 1 250 watts and the power head motor is 175 watts ET 1 for a total of 1 425 watts The SEBO ET 1 12 wide 10 1 2 cleaning width This power head delivers cleaning flexibility because its brush action...

Страница 6: ...ately Also bags and filters can be purchased together in model specific kits called Service Boxes SEBO bags filters and accessories are reasonably priced and widely available To create a fresh scent w...

Страница 7: ...e expectancy of just one SEBO machine Incredible Warranty Coverage All SEBO models include a FREE seven year warranty on the motor and five years on non wear parts and labor charges SEBO s FILTRATION...

Страница 8: ...position on all of the heads brushes and power heads To attach the dusting brush clip 27 locate the two raised ridges on the upper end of the telescopic tube 5 just below the handle Push the clip ont...

Страница 9: ...2 Turbo and K2 Kombi Users Figures 1 2 Before turning on your canister make sure that the vacuum handle is in its upright locked position 1 With the canister main power knob 9 in the OFF position pull...

Страница 10: ...or dusting brush 28 onto the end of the handle To use the upholstery nozzle 11 fit it onto the end of the crevice nozzle 20 After use switch off the power unplug the vacuum and remove the attachment R...

Страница 11: ...out of the bristles manually or vacuum the bristles with the telescopic tube Always unplug vacuum from outlet before dismantling any part of machine To remove a brush or power head switch off the pow...

Страница 12: ...d snap the cover down firmly Figure 17 Figure 19 Figure 20 Always unplug vacuum from outlet before dismantling any part of machine K Filter Set Exhaust Filter and Pre motor Microfilter Part 6696AM Cha...

Страница 13: ...shing the tool release button 7 and pulling the tube out Hold the hose upright with one hand blocking the top and switch on the machine If necessary quickly lift your hand on and off the end of the ho...

Страница 14: ...ee page 8 2 Use another outlet 3 Replace cable 4 K3 Set slider switch to on position See page 10 1 Replace filter bag See page 12 2 See Clog Removal on page 13 K3 users with clog in power head attachm...

Страница 15: ...ing brush 44 6751GS Castor for bottom casing 50 6237ER Telescopic tube stainless steel cpl incl pos 51 54 51 6425ER Sliding knob 52 6238ER Locking mechanism 53 6480ER Release button cpl 54 1736GS Fitt...

Страница 16: ...thermal cut off pos 15 21 6679GS Motor cover 22 6622GS Plug surround 24 6680DR1 Top Casing red 25 25 6625ER Release clip w screw 26 6403DRER Exhaust filter cover red 27 60666WE Power knob white 28 60...

Отзывы: